Chapter 9 Specifications and Option devices
Items
Specifications
Analog
output
l
2 channels (AO1, AO2)
l
-10V ~ 10V Voltage output
l
Selectable among 31 different user-defined functions
Contact output
l
2 channels (1A-1B, 2A-2B)
l
Fault alarm relay: 1 channel (30A-30C, 30B-30C)
O
ut
pu
t
Open Collector
1 Channel (OC1/EG)
Protection function
Overcurrent, Overvoltage, Low voltage, Inverter overheat, Inverter
thermal sensor malfunction, Motor overheat, Motor thermal sensor
malfunction, Overspeed, Instantaneous IGBT gate block (BX), Fuse blown
open, External Trip, Pulse encoder malfunction, Electronic thermal
function, Inverter overload, Ground fault current, IGBT short,
Communication error
Installation condition
Indoor, Free of Corrosive gas and Direct sunlight
Ambient temperature
-10 ~ 40
°
C (Non-frozen condition)
Humidity
Below RH 90% (Dewdrop should not be formed)
Cooling method
Forced ventilation by cooling fan
Altitude, Vibration
Below 1000m above sea level, Below 5.9m/s
2
(=0.6G)
En
vi
ro
nm
en
t
Installation condition
ESD-4 (RH-2)