PUTTING THE WATER HEATER OUT OF OPERATION
It is recommended to have the water heater operational all year round to prevent any frost damage during the winter and/or rotating parts
getting jammed during other times of the year (built in water heater safety features).
O
UT
O
F
O
PERATION
:
O
N
/O
FF
F
UNCTION
.
To be used when the appliance is to be put out of operation for a long period.
Act as follows:
Disconnect or switch off the tank thermostat and/or other external controllers from the water heater. The pump and fan will stop after
a short time.
Switch off the water heater by pressing the [ON/OFF] button for six seconds.
Make sure the following display screen is visible.
Display message
B o i l e r
o f f
Properties of the ‘off’ function:
The keys do NOT respond and the menu is NOT accessible.
The burner does NOT respond to an external heat demand.
The water heater CAN, however, be switched on again by pressing the [ON/OFF] button.
Pump(s), fan(s) and cascade (if applicable) are operational, and so are both recirculation protection (if applicable) and frost
protection.
To reactivate the water heater, switch on the burner by pressing [ON/OFF] for six seconds again.
The frost protection module can still activate the burner(s).To prevent this, switch off this protection or put the water
heater in ‘power off’ mode (next paragraph).
O
UT
O
F
O
PERATION
:
P
OWER
O
FF
.
To assure that the water heater cannot become active at all anymore, power should be cut off completely.
Act as follows:
Disconnect or switch off the tank thermostat and/or other external controllers from the water heater. The pump and fan will stop after
a short time.
Switch off the water heater by pressing the [ON/OFF] button for six seconds.
Make sure the following display screen is visible.
Display message
B o i l e r
o f f
Switch off the electrical power supply of the water heater (remove connection from the wall socket, or switch off the main power).
Close the gas valve / gas supply.
In case of possible frost damage: drain both the water heater and the DHW system.
Before starting to drain the water heater, first start draining the DHW system and subsequently also the two drains
of the water heater.
Содержание EcoForce EF100
Страница 2: ...2 ...
Страница 11: ...11 3 1 4 Cascade frames Frames are available to mount up to 4 EcoForce water heaters if required ...
Страница 24: ...24 ...
Страница 25: ...25 ...
Страница 26: ...26 ...
Страница 30: ...30 ...
Страница 31: ...31 ...
Страница 32: ...32 ...
Страница 33: ...33 ...
Страница 119: ...119 ...
Страница 120: ...120 ...