113
MAINTENANCE
G
ENERAL
Gas appliances should be checked at Maximum intervals of no more than 12 months, this will ensure the safe and reliable operation of the
water heater for many years to come.
Maintenance and inspection of the water heater should be carried out at the following occasions:
When a number of similar error codes and/or lock-outs appear.
A full service and gas safety check must be carried out at least every 12 months to ensure safe and efficient
operation.
Damage caused by lack of maintenance will not be covered under warranty.
M
AINTENANCE
R
EMINDER
F
UNCTION
.
BE AWARE: This function is OFF as standard. This function is to be used for a general reminder only, it cannot be used to lengthen the periods
of Maintenance beyond 12 months and will not be accepted as proof of a suitable Maintenance regime should a warrantable fault occur.
It is and remains the responsibly of the end user to have the unit maintained every twelve months!
Display message
N e e d s
M a i n t e n a n
0 . 0
I g n i
t
i o n
c y c l e s
h r s
Reason
Maintenance option of total amount of ignition cycles has been reached.
Display message
N e e d s
M a i n t e n a n
0 . 0
D a t e
h r s
Reason
Maintenance option of the date has been reached.
Display message
N e e d s
M a i n t e n a n
0 . 0
B u r n i n g
h o u r s
h r s
Reason
Maintenance option of total amount of burning hours has been reached.
Display message
N e e d s
M a i n t e n a n
0 . 0
A l
l
h r s
Reason
One of the abovementioned maintenance options has been reached.
S
ERVICE
I
NTERVALS
The Maximum service interval for the water heater is once a year. Every year the water heater should be cleaned and checked, according to
the maintenance procedures. If there is doubt whether the water heater is operating with the correct water and/or combustion air quality, it is
advised that a first check is executed after the first 6 months. This will determine the frequency of the future service intervals. The maximum
interval between two services can be a year.
It is a condition of the water heater warranty that the boiler must be serviced by a competent engineer registered with an
HSE approved body every 12 months,
W
ATERSIDE
In hard water areas the heat exchanger waterways should be inspected and if necessary a mild descale carried out in order to prevent lime
scale build up within the heat exchanger.
Failure to protect and clean the heat exchanger may result in a non-warrantable heat exchanger failure
Содержание EcoForce EF100
Страница 2: ...2 ...
Страница 11: ...11 3 1 4 Cascade frames Frames are available to mount up to 4 EcoForce water heaters if required ...
Страница 24: ...24 ...
Страница 25: ...25 ...
Страница 26: ...26 ...
Страница 30: ...30 ...
Страница 31: ...31 ...
Страница 32: ...32 ...
Страница 33: ...33 ...
Страница 119: ...119 ...
Страница 120: ...120 ...