DIP SWITCHES FOR 50 SEC. TO 30 MIN. TIMES
CONTROL
1
2
3
4
5
SWITCH POSITION OFF
OFF
ON
OFF
OFF
DIP SWITCHES FOR 23 SEC. TO 30 MIN. TIMES
CONTROL
1
2
3
4
5
SWITCH POSITION OFF
ON
OFF
OFF
OFF
1. With power off, the ten (10) dip switches located on rear of Time/Temp Display (see drawing on page
43) should be set as below.
NOTE
: For time/temp displays using a thermister (2 yellow wires on Terminals 9 & 10), set the dip switches as
follows:
FOR 50 SEC TO 30 MIN CONVEYOR TIMES
DISPLAY
1
2
3
4
5
6
7
8
9
10
SWITCH POSITION
OFF
*
*
ON
ON
OFF
OFF
ON
OFF
ON
For time/temp displays using a thermocouple (red wire on #9 and white wire on #10), set
the dip switches as follows:
DISPLAY
1
2
3
4
5
6
7
8
9
10
SWITCH POSITION
OFF
OFF
*
ON
OFF
OFF
ON
ON
OFF
ON
* Off for °F
* On for °C
FOR 23 SEC. TO 30 MIN. CONVEYOR TIMES
NOTE
: For time/temp displays using a thermistor (2 yellow wires on Terminals 9 & 10), set the dip switches as
follows:
DISPLAY
1
2
3
4
5
6
7
8
9
10
SWITCH POSITION
OFF
*
*
ON
ON
OFF
ON
OFF
ON
ON
*SWITCH 2 - OFF FOR 60HZ, ON FOR 50HZ
*SWITCH 3 - OFF FOR °F, ON FOR °C
For time/temp displays using a thermocouple (red wire on #9 and white wire on #10), set
the dip switches as follows:
DISPLAY
1
2
3
4
5
6
7
8
9
10
SWITCH POSITION
OFF
OFF
*
ON
OFF
OFF
ON
ON
OFF
ON
* Off for °F
* On for °C
1. With conveyor running, set conveyor speed control so Time/Temp. Display indicates 5:00 minutes. Place a pan
on the conveyor, measure (STOPWATCH) the time (SPEED OF PAN) of the leading edge in to leading edge
out of oven. Turn the time adjustment pot. on the rear of the Time/Temp. Display so display agrees with time
measured by the stop watch.
2. Turn conveyor speed control fully counterclockwise and adjust the stepper control maximum speed pot(refer to
drawing Pg. D-19) so the display indicates 50 seconds.
3. Turn conveyor speed control fully clockwise and adjust the stepper control minimum speed pot so the display
indicates 30 minutes.
NOTE:
Repeat 4 and 5 to be sure settings are accurate.
4. Turn power off and set #1 dip switch to its (ON/OFF) other position and verify that the conveyor reverses direction
when power is applied. Set conveyor travel direction as customer requests.
CAUTION: ALWAYS REMOVE POWER BEFORE CHANGING CONVEYOR DIRECTION.
Содержание IMPINGER 1100
Страница 8: ...Impinger II 1100 Series Service Manual Domestic 8 SCHEMATIC 1100 1101 ...
Страница 9: ...Impinger II 1100 Series Service Manual Domestic 9 SCHEMATIC 1102 1103 ...
Страница 10: ...Impinger II 1100 Series Service Manual Domestic 10 SCHEMATIC 1116 1117 S N 2011383 BELOW ...
Страница 11: ...Impinger II 1100 Series Service Manual Domestic 11 SCHEMATIC 1116 1117 S N 2011384 ABOVE ...
Страница 13: ...Impinger II 1100 Series Service Manual Domestic 13 SCHEMATIC 1130 1131 S N 2011384 ABOVE ...
Страница 14: ...Impinger II 1100 Series Service Manual Domestic 14 SCHEMATIC 1160 1161 S N 2011978 ABOVE ...
Страница 16: ...Impinger II 1100 Series Service Manual Domestic 16 SCHEMATIC 1132 1133 S N 2011384 ABOVE ...
Страница 17: ...Impinger II 1100 Series Service Manual Domestic 17 SCHEMATIC 1162 1163 S N 2011978 ABOVE ...
Страница 51: ...Impinger II 1100 Series Service Manual Domestic 51 BLOW UP GENERAL 1100 SERIES ...
Страница 55: ...Impinger II 1100 Series Service Manual Domestic 55 BLOW UP CONTROL COMPARTMENT FRONT 1116 1117 ...
Страница 65: ...Impinger II 1100 Series Service Manual Domestic 65 BLOW UP OVEN BACK ASSEMBLY 1100 SERIES ...
Страница 67: ...Impinger II 1100 Series Service Manual Domestic 67 BLOW UP GEARMOTOR ASSEMBLY 1100 SERIES ...
Страница 69: ...Impinger II 1100 Series Service Manual Domestic 69 BLOW UP CONVEYOR DOOR 1100 SERIES ...
Страница 71: ...Impinger II 1100 Series Service Manual Domestic 71 This page intentionally left blank ...
Страница 72: ...Impinger II 1100 Series Service Manual Domestic 72 ...