![Lincoln IMPINGER 1100 Скачать руководство пользователя страница 24](http://html1.mh-extra.com/html/lincoln/impinger-1100/impinger-1100_service-manual_1917751024.webp)
Impinger II –1100 Series Service Manual - Domestic
24
TROUBLESHOOTING GUIDE 1130 THRU 1133 / 1160 THRU 1163
ELECTRIC OVENS
MODEL 1130, 1160 / 120/208 VAC / SINGLE PHASE / 60 HZ
MODEL 1131, 1161 / 120/240 VAC / SINGLE PHASE / 60 HZ
MODEL 1132, 1162 / 120/208 VAC / THREE PHASE / 60 HZ
MODEL 1133, 1163 / 120/240 VAC / THREE PHASE / 60 HZ
REFER TO PROPER SCHEMATIC FOR INDENTIFIED COMPONENTS
SYMPTON
POSSIBLE CAUSE
EVALUATION
Oven fan will not run
Incoming Power Supply
Check circuit breakers. Reset if required. Call Power
Co. if needed.
NOTE:
On Models 1160, 1161, 1162 and 1163,
disconnect any accessory from receptacle in the rear
of the oven and check for shorts or overloads.
Fuses, 10 Amp,
Check, replace if necessary
Fuseholder
Check, replace if necessary
High Limit Thermostat, Oven
Cavity
Terminals are normally closed. If open, reset the
thermostat and test for proper operation. If it will not
reset and hold, replace thermostat.
Switch, Main Fan
Check for continuity between switch terminals.
Relay, Oven Start
Check for continuity at relay coil, and visually check
for pull in of contacts.
20 Minute Time Delay
Check for 120 VAC at terminal #1 to neutral on 20
minute Time Delay Relay. If no voltage is present,
trace wiring
back to 10A fuse. If voltage is present
at terminal #1, check for 120 VAC at terminal #2 to
neutral. If no voltage is present, and oven start relay is
closed, replace Time Delay.
Main Fan Relay
Check for 120 VAC to coil of the Relay. If no voltage is
present, trace wiring back to 20 minute Time Delay
Relay. If voltage is present, check to insure contacts
are closing.
Main Fan Motor
Check for opens, shorts, or grounds. WITH POWER
OFF: Turn fan blade to check for locked rotor.
Capacitor
Check for opens, shorts, or grounds
No main fan cool down 20 Minute Time Delay
Check for 120 VAC at terminal #2 to neutral while
oven is "on". Turn off the main fan switch, 120 VAC
should continue to be present for 20 minutes. If
voltage is not present for approx. 20 minutes, replace
the timer.
Oven Fan Relay
Check if relay is operating and that the contacts
remain closed during the 20 minute cool down.
Main fan runs after 20
minute cool down
Oven Start Relay
Contacts should open when main fan switch is turned
off.
20 Minute Time Delay
120 VAC at terminal #2 should discontinue
approximately 20 minutes after main fan is switched
off. If the oven start relay contacts are open, and the
voltage continues at terminal #2 of the 20 minute
timer, for more than 20 minutes, replace the timer.
Oven Fan Relay
Check to insure that the contacts are opening after the
coil is de-energized
20 Minute Time Delay
NOTE
: ON/OFF operation of the fan switch will set the
timer to 20 minutes. If the timer is accidentally reset,
turn off main breaker for 15 seconds to cancel
Содержание IMPINGER 1100
Страница 8: ...Impinger II 1100 Series Service Manual Domestic 8 SCHEMATIC 1100 1101 ...
Страница 9: ...Impinger II 1100 Series Service Manual Domestic 9 SCHEMATIC 1102 1103 ...
Страница 10: ...Impinger II 1100 Series Service Manual Domestic 10 SCHEMATIC 1116 1117 S N 2011383 BELOW ...
Страница 11: ...Impinger II 1100 Series Service Manual Domestic 11 SCHEMATIC 1116 1117 S N 2011384 ABOVE ...
Страница 13: ...Impinger II 1100 Series Service Manual Domestic 13 SCHEMATIC 1130 1131 S N 2011384 ABOVE ...
Страница 14: ...Impinger II 1100 Series Service Manual Domestic 14 SCHEMATIC 1160 1161 S N 2011978 ABOVE ...
Страница 16: ...Impinger II 1100 Series Service Manual Domestic 16 SCHEMATIC 1132 1133 S N 2011384 ABOVE ...
Страница 17: ...Impinger II 1100 Series Service Manual Domestic 17 SCHEMATIC 1162 1163 S N 2011978 ABOVE ...
Страница 51: ...Impinger II 1100 Series Service Manual Domestic 51 BLOW UP GENERAL 1100 SERIES ...
Страница 55: ...Impinger II 1100 Series Service Manual Domestic 55 BLOW UP CONTROL COMPARTMENT FRONT 1116 1117 ...
Страница 65: ...Impinger II 1100 Series Service Manual Domestic 65 BLOW UP OVEN BACK ASSEMBLY 1100 SERIES ...
Страница 67: ...Impinger II 1100 Series Service Manual Domestic 67 BLOW UP GEARMOTOR ASSEMBLY 1100 SERIES ...
Страница 69: ...Impinger II 1100 Series Service Manual Domestic 69 BLOW UP CONVEYOR DOOR 1100 SERIES ...
Страница 71: ...Impinger II 1100 Series Service Manual Domestic 71 This page intentionally left blank ...
Страница 72: ...Impinger II 1100 Series Service Manual Domestic 72 ...