THERMOCOUPLE MEASUREMENT CHART:
EXPLANATION: The junction temperature is the ambient air temperature where the
thermocouple fastens to the electronic temperature control board.
O
V
E
N
T
E
M
P
200°F 250°F 300°F 325°F 350°F 400°F 425°F 450°F 500°F 550°F 600°F
J
90°F 3.26
4.77
6.30
7.06
7.83
9.37 10.14 10.91 12.46 14.00 15.53
U
88°F 3.32
4.83
6.36
7.12
7.89
9.43 10.20 10.97 12.51 14.05 15.59
N
86°F 3.37
4.88
6.41
7.17
7.94
9.49 10.26 11.03 12.57 14.11 15.65
C
84°F 3.43
4.94
6.47
7.23
8.00
9.54 10.31 11.09 12.63 14.19 15.71
T
82°F 3.49
5.00
6.53
7.29
8.06
9.60 10.37 11.14 12.69 14.23 15.76
I
80°F 3.55
5.06
6.59
7.35
8.12
9.66 10.43 11.20 12.74 14.28 15.82
O
78°F 3.60
5.11
6.64
7.40
8.17
9.72 10.49 11.26 12.80 14.34 15.86
N
76°F 3.66
5.17
6.70
7.46
8.23
9.77 10.55 11.32 12.86 14.40 15.94
75°F 3.69
5.20
6.73
7.49
5.26
9.80 10.57 11.35 12.89 14.43 15.97
74°F 3.72
5.23
6.76
7.52
8.29
9.83 10.60 11.37 12.92 14.46 15.99
72°F 3.78
5.29
6.82
7.58
8.35
9.89 10.66 11.43 12.97 14.51 16.05
T
70°F 3.83
5.34
6.87
7.63
8.40
9.95 10.72 11.49 13.03 14.57 16.11
E
68°F 3.89
5.40
6.93
7.69
8.46
10.00 10.78 11.55 13.09 14.63 16.17
M
66°F 3.95
5.46
6.99
7.75
8.52
10.06 10.83 11.61 13.15 14.69 16.23
P
64°F 4.01
5.52
7.05
7.81
8.58
10.12 10.89 11.66 13.20 14.74 16.28
62°F 4.06
5.57
7.10
7.86
8.63
10.18 10.95 11.72 13.26 14.80 16.34
60°F 4.12
5.63
7.16
7.92
8.69
10.24 11.01 11.78 13.32 14.86 16.40
MERCURY CONTACTOR
1. Shut off power at the main breaker.
2. Remove conveyor.
3. Remove control compartment covers.
4. Disconnect contactor wires and mark for reinstallation.
5. Remove screws from mounting bracket and replace contactor.
NOTE
: Be sure contactor is not mounted upside down at this will cause a constant on condition.
6. Reassemble in reverse order.
GAS VALVE
1. Shut off power at main breaker.
2. Shut off the gas supply in the main line to the oven.
3. Disconnect the flexible gas hose.
4. Remove the control compartment covers.
5. Remove the manual gas shut off valve from piping.
6. Remove screws from the bulkhead plate located on rear of oven at the gas pipe.
7. Remove the section of gas pipe to gas valve.
8. Disconnect the electrical leads from the solenoid valve.
9. Loosen the gas line union located near the burner and remove the gas valve and
solenoid valve assembly.
10. Finish removal of the gas piping from gas valve.
11. Replace in reverse order.
12. Check all gas fittings for leaks.
13. Adjust the gas manifold pressure on the gas valve. "Refer to the specification plate
on the oven for proper rating".
SOLENOID VALVE
1. Shut off power at main breaker.
2. Shut off gas supply.
3. Remove rear control box cover.
4. Disconnect wires from solenoid valve. Mark wires for reassembly.
5. Loosen pipe union in piping assembly.
Содержание IMPINGER 1100
Страница 8: ...Impinger II 1100 Series Service Manual Domestic 8 SCHEMATIC 1100 1101 ...
Страница 9: ...Impinger II 1100 Series Service Manual Domestic 9 SCHEMATIC 1102 1103 ...
Страница 10: ...Impinger II 1100 Series Service Manual Domestic 10 SCHEMATIC 1116 1117 S N 2011383 BELOW ...
Страница 11: ...Impinger II 1100 Series Service Manual Domestic 11 SCHEMATIC 1116 1117 S N 2011384 ABOVE ...
Страница 13: ...Impinger II 1100 Series Service Manual Domestic 13 SCHEMATIC 1130 1131 S N 2011384 ABOVE ...
Страница 14: ...Impinger II 1100 Series Service Manual Domestic 14 SCHEMATIC 1160 1161 S N 2011978 ABOVE ...
Страница 16: ...Impinger II 1100 Series Service Manual Domestic 16 SCHEMATIC 1132 1133 S N 2011384 ABOVE ...
Страница 17: ...Impinger II 1100 Series Service Manual Domestic 17 SCHEMATIC 1162 1163 S N 2011978 ABOVE ...
Страница 51: ...Impinger II 1100 Series Service Manual Domestic 51 BLOW UP GENERAL 1100 SERIES ...
Страница 55: ...Impinger II 1100 Series Service Manual Domestic 55 BLOW UP CONTROL COMPARTMENT FRONT 1116 1117 ...
Страница 65: ...Impinger II 1100 Series Service Manual Domestic 65 BLOW UP OVEN BACK ASSEMBLY 1100 SERIES ...
Страница 67: ...Impinger II 1100 Series Service Manual Domestic 67 BLOW UP GEARMOTOR ASSEMBLY 1100 SERIES ...
Страница 69: ...Impinger II 1100 Series Service Manual Domestic 69 BLOW UP CONVEYOR DOOR 1100 SERIES ...
Страница 71: ...Impinger II 1100 Series Service Manual Domestic 71 This page intentionally left blank ...
Страница 72: ...Impinger II 1100 Series Service Manual Domestic 72 ...