Impinger II –1100 Series Service Manual - Domestic
18
TROUBLESHOOTING GUIDE 1116 - 1117
GAS OVENS
MODEL 1116 / NATURAL GAS / 120VAC / 60 HZ / 1 PHASE
MODEL 1117 / L.P. GAS / 120VAC / 60 HZ / 1 PHASE
REFER TO PROPER SCHEMATIC FOR IDENTIFIED COMPONENTS
SYMPTOM
POSSIBLE CAUSE
EVALUATION
Oven fan will not run
Incoming Power Supply
Check breakers/Reset if required Check power plug to
be sure it is firmly in receptacle. Measure incoming
power/call Power Co. if needed.
Main Fan Switch
Check continuity between switch terminal.
20 Minute Time Delay
Check for 120 VAC at terminal #1 to neutral on 20
minute Time Delay Relay. If no voltage is present,
trace wiring back to power source. If voltage is present
at terminal #1, check for 120 VAC at terminal #2 to
neutral. If no voltage is present, and Main Fan Switch
is closed, replace Time Delay
Main Fan Relay
Check for 120 VAC to coil of the Relay, if no voltage
is present, trace wiring back
to 20 minute Time
Delay Relay.
If voltage is present, check to insure
contacts are closing.Fuse, 10 Amp Check, replace if
necessary
Fuse Holder
Check, replace if necessary.
Main Fan Motor
Check for opens, shorts, or grounds. WITH POWER
OFF: turn fan blade to check for locked rotor.
Capacitor
Check for shorts or grounds. WARNING: Capacitor
has a stored
charge, discharge before testing.
No main fan cool down
Main fan runs after 20
minute cool down
20 minute cool down
20 Minute Time Delay Relay
Main Fan Relay
Check for 120 VAC at pin #2 and #3 while main fan is
running. Turn off main fan switch and 120 VAC should
continue to be present for 20 minutes at terminal 2.
Check if relay is operating and terminals are remaining
closed for main fan cool down of 20 minutes
NOTE
: The time delay relay will keep the coil of main fan relay
closed, maintaining main fan operation for cool down for
approximately 20 minutes.
Time Delay Relay
120 VAC at terminal 2 should discontinue
approximately 20 minutes after the main fan switch is
switched off. If the switch is open and voltage
continues at terminal 2, replace Time Delay. When
voltage at terminal 2 of Time Delay ceases ,the main
fan relay must open.
No control box cooling
Incoming Power
Check main circuit breakers, reset if required, call power
company if needed.
Main Fan Switch
Check continuity between switch terminals.
20 Minute Time Delay
With fan switch on, check for 120 VAC at terminal 2 of
Time Delay.
Main Fan Relay
Check continuity of 120 VAC coil. Check for power to
the relay coil (120 VAC).
Cooling Fans
120 VAC should now be at the fan motors. If voltage is
present, check motors for shorts or opens WITH
POWER OFF: Check for locked rotor.
Содержание IMPINGER 1100
Страница 8: ...Impinger II 1100 Series Service Manual Domestic 8 SCHEMATIC 1100 1101 ...
Страница 9: ...Impinger II 1100 Series Service Manual Domestic 9 SCHEMATIC 1102 1103 ...
Страница 10: ...Impinger II 1100 Series Service Manual Domestic 10 SCHEMATIC 1116 1117 S N 2011383 BELOW ...
Страница 11: ...Impinger II 1100 Series Service Manual Domestic 11 SCHEMATIC 1116 1117 S N 2011384 ABOVE ...
Страница 13: ...Impinger II 1100 Series Service Manual Domestic 13 SCHEMATIC 1130 1131 S N 2011384 ABOVE ...
Страница 14: ...Impinger II 1100 Series Service Manual Domestic 14 SCHEMATIC 1160 1161 S N 2011978 ABOVE ...
Страница 16: ...Impinger II 1100 Series Service Manual Domestic 16 SCHEMATIC 1132 1133 S N 2011384 ABOVE ...
Страница 17: ...Impinger II 1100 Series Service Manual Domestic 17 SCHEMATIC 1162 1163 S N 2011978 ABOVE ...
Страница 51: ...Impinger II 1100 Series Service Manual Domestic 51 BLOW UP GENERAL 1100 SERIES ...
Страница 55: ...Impinger II 1100 Series Service Manual Domestic 55 BLOW UP CONTROL COMPARTMENT FRONT 1116 1117 ...
Страница 65: ...Impinger II 1100 Series Service Manual Domestic 65 BLOW UP OVEN BACK ASSEMBLY 1100 SERIES ...
Страница 67: ...Impinger II 1100 Series Service Manual Domestic 67 BLOW UP GEARMOTOR ASSEMBLY 1100 SERIES ...
Страница 69: ...Impinger II 1100 Series Service Manual Domestic 69 BLOW UP CONVEYOR DOOR 1100 SERIES ...
Страница 71: ...Impinger II 1100 Series Service Manual Domestic 71 This page intentionally left blank ...
Страница 72: ...Impinger II 1100 Series Service Manual Domestic 72 ...