Impinger II –1100 Series Service Manual - Domestic
25
No control box cooling
Check for main fan operation. If not operating, refer to
"Oven Fan Will Not Run".
Oven Start Relay
Check relay contacts. 120 VAC should be present.
Cooling Fan Motor(s)
120 VAC should be present at the fan motor. If voltage
is present, check for opens or shorts. WITH POWER
OFF: Check for locked rotor of the fan motor.
No automatic control
Thermostat, Cooling
Check the cooling fan thermostat. box cooling Fan
(Thermostat closes at 120°F and opens at 100°F.).
With the cooling fan thermostat pre-heated, check for
continuity. If switch is open, replace.
Cooling Fan Motor(s)
120 VAC should be present at the fan motor. If voltage
is present, check for opens or shorts. WITH POWER
OFF: check for locked rotor of the fan motor.
Control box cooling fan
continues to run
Thermostat, Cooling Fan
This normally open thermostat should close at 120°F
(48.9°C) and reopen at 100°F (37.8°C).
Oven will not heat
Main Fan Motor
Check for main fan operation. If it is not operating,
refer to "Oven fan will not run".
Heat Switch
With switch on, check for 120 VAC on both terminals
to neutral. Replace if defective.
Air Pressure Switch
This normally open switch should close when the main
fan is activated. Adjust if necessary (Refer to page
23). Replace if defective.
Fuse, 3 Amp
Check, replace if necessary
Fuseholder
Check, replace if necessary
Temperature Control
Check for 120 VAC supply at terminal #11 to neutral
on temperature control. If no voltage is present, trace
wiring back to 3-amp fuse. Turn the temperature
adjustment knob to maximum temperature position
and check for 120 VAC at the load terminal (#9) and
neutral. If 120 VAC is present and unit is not heating,
refer to "Mercury Contactor" for next check. If 120
VAC is not present, proceed.
Thermocouple Probe
WITH POWER ON AND THERMOCOUPLE LEADS
ATTACHED TO THE TEMPERATURE CONTROL
BOARD: measure D. C. millivolt output of these leads.
Refer to thermocouple chart on page 36 for proper
readings. If these readings are not achieved, replace
thermocouple.
Temperature Control
Potentiometer
WITH POWER OFF: remove the potentiometer leads
from the temperature control board and measure
ohms from black to white leads. The reading should
be from approximately 0 to 2.5k ohms as the dial of
the potentiometer is turned throughout its full rotation.
From black to red leads, the reading should be
approximately 2.5k ohms (constant) throughout the full
rotation of the dial. If these readings are not achieved,
replace the potentiometer. If the thermocouple probe
and the control potentiometer check good, then the
problem is usually with the temperature control board.
Mercury Contactor
Check for 120 VAC to the contactor coil. If voltage is
present and the contactor will not activate, replace the
contactor. Also, check each contactor for proper high
voltage input and output.
Heater Elements
Check the Amp. draw on each hot leg for proper load.
Check the specifications plate for rating information. If
the Amp. draw is low or high, check the individual
elements for opens, shorts, and proper resistance.
WITH POWER OFF: To check resistance of the
elements, remove all leads from the elements and use
an accurate digital VOM. The element resistance
should be as follows: 208V - 27 ohms approximately
Содержание IMPINGER 1100
Страница 8: ...Impinger II 1100 Series Service Manual Domestic 8 SCHEMATIC 1100 1101 ...
Страница 9: ...Impinger II 1100 Series Service Manual Domestic 9 SCHEMATIC 1102 1103 ...
Страница 10: ...Impinger II 1100 Series Service Manual Domestic 10 SCHEMATIC 1116 1117 S N 2011383 BELOW ...
Страница 11: ...Impinger II 1100 Series Service Manual Domestic 11 SCHEMATIC 1116 1117 S N 2011384 ABOVE ...
Страница 13: ...Impinger II 1100 Series Service Manual Domestic 13 SCHEMATIC 1130 1131 S N 2011384 ABOVE ...
Страница 14: ...Impinger II 1100 Series Service Manual Domestic 14 SCHEMATIC 1160 1161 S N 2011978 ABOVE ...
Страница 16: ...Impinger II 1100 Series Service Manual Domestic 16 SCHEMATIC 1132 1133 S N 2011384 ABOVE ...
Страница 17: ...Impinger II 1100 Series Service Manual Domestic 17 SCHEMATIC 1162 1163 S N 2011978 ABOVE ...
Страница 51: ...Impinger II 1100 Series Service Manual Domestic 51 BLOW UP GENERAL 1100 SERIES ...
Страница 55: ...Impinger II 1100 Series Service Manual Domestic 55 BLOW UP CONTROL COMPARTMENT FRONT 1116 1117 ...
Страница 65: ...Impinger II 1100 Series Service Manual Domestic 65 BLOW UP OVEN BACK ASSEMBLY 1100 SERIES ...
Страница 67: ...Impinger II 1100 Series Service Manual Domestic 67 BLOW UP GEARMOTOR ASSEMBLY 1100 SERIES ...
Страница 69: ...Impinger II 1100 Series Service Manual Domestic 69 BLOW UP CONVEYOR DOOR 1100 SERIES ...
Страница 71: ...Impinger II 1100 Series Service Manual Domestic 71 This page intentionally left blank ...
Страница 72: ...Impinger II 1100 Series Service Manual Domestic 72 ...