Impinger II –1100 Series Service Manual - Domestic
40
11. Install the optical encoder, refer to "OPTICAL ENCODER" in this section for adjustment.
NOTE
: The thin, slotted encoder disc must be handled with care so not to bend it.
12. Recheck tightness on the set screws to be sure they are tight. If available,
LOC TITE (the removable kind) should be used to secure set screws.
OPTICAL ENCODER ASSEMBLY
1. Remove gearmotor assembly (see "GEARMOTOR") Above.
2. If replacing with new assembly, cut wires to remove as new wires and plug are provided. If only
removing for access to coupling, see step 3.
3. Remove pins from connector with pin extractor tool, P/N 369600.
4. Loosen dust cover screws and pull dust cover away from motor.
5. Remove 2 screws from optical encoder and remove encoder.
6. Reassemble in reverse order.
7. To adjust optical encoder:
a. Position the encoder assembly so it does not rub the coupler hub and is
square with the encoder disc. The infrared light beam will be broken
by slots in the encoder disc. The encoder disc should not touch the bottom
or top of the optical encoder, if it does, readjust the coupling. The digital
speed readout may be observed to check proper adjustment of the optical
TACH. GENERATOR
1. Turn off power at main breaker.
2. Remove gearmotor assembly (see "GEARMOTOR")
3. Remove tach. cover plate and tach. leads. Mark wires for reassembly.
4. Remove 2 slotted screws from dust cover base and remove dust cover.
5. Loosen coupling set screw (.050 inch allen wrench).
6. Remove tach. bracket from motor. (4 screws)
7. Remove 4 screws from base of tach. and tach. is now free for removal.
8. Reassemble in reverse order. Maintain spacing of .010 minimum between tach.bracket and coupler hub.
NOTE
: If a new tach. generator is installed, the D.C. motor control board MUST
BERECALIBRATED. There is no repair procedure for the tach. If defective, replace.
D. C. MOTOR CONTROL BOARD
4 A. FUSE
1 A. FUSE
.
RESISTOR
L 1
A+
L 2
A -
T 1
T 2
MAX
MIN IR
CL TACH
BOARD P/N 369155
STYLE 1
P 3
P 2
P 1
4 A. FUSE
1 A. FUSE
RESISTOR
L 1
A+
L 2
A -
T 1
T 2
BOARD P/N 369155
STYLE 2
P 3
P 2
P 1
MAX
MIN
L 1
L 2
A +
A -
T 2
T 1
S 3
S 2
S 1
MIN MAX
CAPACITOR
BOARD P/N 369155
STYLE 3
RESISTOR
Three different styles of control boards have been used and all three are still usable.
All three were supplied under the same part number.
TO REPLACE THE CONTROL BOARD
:
1. Turn off power at main breaker and remove front control compartment cover.
2. Remove conveyor.
3. Remove and mark all wires from board
4. Remove control board bracket and board from unit, 3 screws.
5. Remove control board from mounting bracket. Remove 4 screws, lockwashers, and nuts.
Содержание IMPINGER 1100
Страница 8: ...Impinger II 1100 Series Service Manual Domestic 8 SCHEMATIC 1100 1101 ...
Страница 9: ...Impinger II 1100 Series Service Manual Domestic 9 SCHEMATIC 1102 1103 ...
Страница 10: ...Impinger II 1100 Series Service Manual Domestic 10 SCHEMATIC 1116 1117 S N 2011383 BELOW ...
Страница 11: ...Impinger II 1100 Series Service Manual Domestic 11 SCHEMATIC 1116 1117 S N 2011384 ABOVE ...
Страница 13: ...Impinger II 1100 Series Service Manual Domestic 13 SCHEMATIC 1130 1131 S N 2011384 ABOVE ...
Страница 14: ...Impinger II 1100 Series Service Manual Domestic 14 SCHEMATIC 1160 1161 S N 2011978 ABOVE ...
Страница 16: ...Impinger II 1100 Series Service Manual Domestic 16 SCHEMATIC 1132 1133 S N 2011384 ABOVE ...
Страница 17: ...Impinger II 1100 Series Service Manual Domestic 17 SCHEMATIC 1162 1163 S N 2011978 ABOVE ...
Страница 51: ...Impinger II 1100 Series Service Manual Domestic 51 BLOW UP GENERAL 1100 SERIES ...
Страница 55: ...Impinger II 1100 Series Service Manual Domestic 55 BLOW UP CONTROL COMPARTMENT FRONT 1116 1117 ...
Страница 65: ...Impinger II 1100 Series Service Manual Domestic 65 BLOW UP OVEN BACK ASSEMBLY 1100 SERIES ...
Страница 67: ...Impinger II 1100 Series Service Manual Domestic 67 BLOW UP GEARMOTOR ASSEMBLY 1100 SERIES ...
Страница 69: ...Impinger II 1100 Series Service Manual Domestic 69 BLOW UP CONVEYOR DOOR 1100 SERIES ...
Страница 71: ...Impinger II 1100 Series Service Manual Domestic 71 This page intentionally left blank ...