Impinger II –1100 Series Service Manual - Domestic
26
240V - 36 ohms approximately.
Oven heats with switch
off
Mercury Contactor
The mercury contactor has probably malfunctioned in
the closed position. If there is no voltage to the
operating coil, but there is high voltage at the
contactor output, replace the mercury contactor.
Intermittent Heating
Thermal/Overload of Motor
The main fan motor is equipped with internal thermal
protection and will cease to operate if overheating
occurs. As the motor overheats and then cools, this
will cause the units to cycle on and off intermittently.
This may be caused by improper ventilation or
preventative maintenance. Also, most of the problems
listed under "Oven will not heat" can cause intermittent
failure.
Conveyor Will Not Run Conveyor Switch
Check for continuity between switch terminals
3 Amp Fuse
Check, replace as needed
Fuseholder
Check, replace as needed
S/N 2011383 and
above 1130 through
1133 – S/N 2011978
and above Models
1160 through 1163
Refer to Page 29
Speed Adjustment
Potentiometer
This is a 0 to 5 K ohm, 10 turn potentiometer. WITH
POWER OFF: Remove the red, black and white pot
leads from the motor control board at terminals P1, P2
and P3. With a digital multimeter, check the ohm
reading across the red lead (P3) to the black lead
(P1). This reading should be 5 K ohms ± 5% as the
pot is rotated from low to high. Place the meter leads
on the red lead (P3) and on the white lead (P2)
Rotating the pot. slowly, from low to high, the meter
reading should show an even transition from 0 to 5 K
ohms ± 5%. There should be no dead or open spots
through out the 10 turns of the pot. Check all three
leads to ground. There should be no continuity to
ground. If any of the above checks fail, replace the
pot.
DC Motor Control Board
Check for 120 VAC input to the control board at
terminals L1 and L2. If not present, check the
conveyor switch and wiring back to 3 amp fuse and
then back to power source if necessary. If 120 VAC is
present at L1 and L2, check the VDC output at
terminals A+ and A-. If a DC voltage is not present,
check the 4 amp and the 1 amp fuses on thecontrol
board. If 120 VAC is present at terminals L1 and L2,
but DC Voltage is not present at A+ and A-, providing
the fuses are good, replace the board. If DC voltage
is present at A+ and A-, but motor does not run, check
gear motor as follows.
Conveyor Gear Motor
If DC voltage is present at A+ and A-and the motor
does not run, first check the mini breaker and then the
conveyor. As described below under "conveyor."
WITH POWER OFF: Check the leads to the motor for
evidence of any shorts or opens, and each lead to
ground. Remove dust cover from the top of the motor
and rotate motor shaft to determine if there is a locked
rotor or a locked gear box (use care so encoder disc is
not damaged). If the motor fails the above tests,
replace motor.
Conveyor
Check for any mechanical misalignment or improper
adjustment. Also check for worn bearings. The
Installation and Operations Manual shows proper
conveyor belt position. A conveyor belt that is too tight
will contribute to excessive load, bearing wear, and
wearing of slider bed rods.
Conveyor speed
varying or intermittent
Power Supply
Check power supply at the DC control board for the
120 VAC at board terminals L1 and L2. If voltage is
not present and steady, check the main circuit
Содержание IMPINGER 1100
Страница 8: ...Impinger II 1100 Series Service Manual Domestic 8 SCHEMATIC 1100 1101 ...
Страница 9: ...Impinger II 1100 Series Service Manual Domestic 9 SCHEMATIC 1102 1103 ...
Страница 10: ...Impinger II 1100 Series Service Manual Domestic 10 SCHEMATIC 1116 1117 S N 2011383 BELOW ...
Страница 11: ...Impinger II 1100 Series Service Manual Domestic 11 SCHEMATIC 1116 1117 S N 2011384 ABOVE ...
Страница 13: ...Impinger II 1100 Series Service Manual Domestic 13 SCHEMATIC 1130 1131 S N 2011384 ABOVE ...
Страница 14: ...Impinger II 1100 Series Service Manual Domestic 14 SCHEMATIC 1160 1161 S N 2011978 ABOVE ...
Страница 16: ...Impinger II 1100 Series Service Manual Domestic 16 SCHEMATIC 1132 1133 S N 2011384 ABOVE ...
Страница 17: ...Impinger II 1100 Series Service Manual Domestic 17 SCHEMATIC 1162 1163 S N 2011978 ABOVE ...
Страница 51: ...Impinger II 1100 Series Service Manual Domestic 51 BLOW UP GENERAL 1100 SERIES ...
Страница 55: ...Impinger II 1100 Series Service Manual Domestic 55 BLOW UP CONTROL COMPARTMENT FRONT 1116 1117 ...
Страница 65: ...Impinger II 1100 Series Service Manual Domestic 65 BLOW UP OVEN BACK ASSEMBLY 1100 SERIES ...
Страница 67: ...Impinger II 1100 Series Service Manual Domestic 67 BLOW UP GEARMOTOR ASSEMBLY 1100 SERIES ...
Страница 69: ...Impinger II 1100 Series Service Manual Domestic 69 BLOW UP CONVEYOR DOOR 1100 SERIES ...
Страница 71: ...Impinger II 1100 Series Service Manual Domestic 71 This page intentionally left blank ...
Страница 72: ...Impinger II 1100 Series Service Manual Domestic 72 ...