Impinger II –1100 Series Service Manual - Domestic
44
FOR DISPLAYS WITH THERMISTOR PROBE ONLY
test leads here
reading should be 26 ± .5 ohms if not, adjust.
pot. range 0-34 ohms
BOTTOM OF TIME TEMP DISPLAY
TIME CALIBRATION
1. Be sure dip switch settings are proper.
2. Turn power on.
3. Turn conveyor on.
4. Place an object on the conveyor belt and time with a stopwatch, the elapsed time for the object to travel
through the oven (leading edge in to leading edge out).
5. Push in and hold the set button. (Discontinued on newer models)
6. Adjust time pot. (rear of display) so display agrees with your stop watch time.
7. Seal pot. with Glyptol or nail polish.
THERMISTOR PROBE REPLACEMENT
1. Shut off power at the main breaker.
2. Remove conveyor and fingers from oven.
3. Remove control compartment covers.
4. Disconnect the 2 yellow thermistor leads from terminals 9 and 10 on the rear of the time/temp. display.
5. Remove the sensing bulb of the thermistor probe from its wire form holder located at right inside rear of the
oven.
6. Install in reverse order.
NOTE
: Be sure that the spring holder is holding the sensor bulb firmly. If the sensor is not held firmly,
compress the wire form slightly to increase pressure.
To test the thermistor probe, refer to the following chart and instructions:
OVEN TEMPERATURE
300°F
325°F
350°F
400°F
425°F
450°F
500°F
550°F
OHMS
182
138
102
62
48
38
24
16
1. Place test pyrometer thermocouple and preheat oven as specified under temperature calibration on page 43.
2. Disconnect the thermistor probe from terminals 9 and 10 and measure the resistance across the 2 yellow
leads.
3. Refer to the above chart to determine if probe is producing the proper resistance.
EXAMPLE
: The probe resistance at 500°F(260°C) should be 24 ohms.
SWITCH, DISPLAY, SET
1. Shut off power at main breaker.
2. Remove conveyor.
3. Remove front control compartment cover.
4. Disconnect wires from time/temp. display terminals 5 and 6.
5. Pull off black operating knob and remove hex mounting nut.
6. Reassemble in reverse order.
Содержание IMPINGER 1100
Страница 8: ...Impinger II 1100 Series Service Manual Domestic 8 SCHEMATIC 1100 1101 ...
Страница 9: ...Impinger II 1100 Series Service Manual Domestic 9 SCHEMATIC 1102 1103 ...
Страница 10: ...Impinger II 1100 Series Service Manual Domestic 10 SCHEMATIC 1116 1117 S N 2011383 BELOW ...
Страница 11: ...Impinger II 1100 Series Service Manual Domestic 11 SCHEMATIC 1116 1117 S N 2011384 ABOVE ...
Страница 13: ...Impinger II 1100 Series Service Manual Domestic 13 SCHEMATIC 1130 1131 S N 2011384 ABOVE ...
Страница 14: ...Impinger II 1100 Series Service Manual Domestic 14 SCHEMATIC 1160 1161 S N 2011978 ABOVE ...
Страница 16: ...Impinger II 1100 Series Service Manual Domestic 16 SCHEMATIC 1132 1133 S N 2011384 ABOVE ...
Страница 17: ...Impinger II 1100 Series Service Manual Domestic 17 SCHEMATIC 1162 1163 S N 2011978 ABOVE ...
Страница 51: ...Impinger II 1100 Series Service Manual Domestic 51 BLOW UP GENERAL 1100 SERIES ...
Страница 55: ...Impinger II 1100 Series Service Manual Domestic 55 BLOW UP CONTROL COMPARTMENT FRONT 1116 1117 ...
Страница 65: ...Impinger II 1100 Series Service Manual Domestic 65 BLOW UP OVEN BACK ASSEMBLY 1100 SERIES ...
Страница 67: ...Impinger II 1100 Series Service Manual Domestic 67 BLOW UP GEARMOTOR ASSEMBLY 1100 SERIES ...
Страница 69: ...Impinger II 1100 Series Service Manual Domestic 69 BLOW UP CONVEYOR DOOR 1100 SERIES ...
Страница 71: ...Impinger II 1100 Series Service Manual Domestic 71 This page intentionally left blank ...
Страница 72: ...Impinger II 1100 Series Service Manual Domestic 72 ...