Thermocouple Probe
WITH POWER ON AND THERMOCOUPLE LEADS
ATTACHED TO THE TEMPERATURE CONTROL
BOARD: Measure the D. C. millivolt output of these
leads. Refer to thermocouple chart on page 36 for
proper readings. If these readings are not achieved,
replace the thermocouple
Temperature Control
Potentiometer
WITH POWER OFF: remove the potentiometer leads
from the temperature control board and measure ohms
from black to white leads. The reading should be from
approximately 0 to 2.5 K ohms as the dial of the
potentiometer is turned throughout its full rotation.
From black to red leads, the reading should be
approximately 2.5 K ohms (constant) throughout the full
rotation of the dial. If these readings are not achieved,
replace potentiometer. If the thermocouple probe and
the control potentiometer check good, then the problem
is usually with the temperature control board.
Temperature Solenoid
If 120 VAC is present on the Valve temperature control
board at load terminal (#9) to neutral, check for voltage
at temperature regulation valve. If voltage is present,
listen for valve to open and close. Also check for opens
or shorts in the coil. Replace as necessary.
Intermittent Heating
Thermal/Overload of Main
Fan and Burner Blower
Motors
.
Conveyor will not run REFER TO PAGE 26
From S/N 2011383 and up REFER TO PAGE 29
Conveyor speed varying or intermittent REFER TO PAGE 26
From S/N 2011383 and up REFER TO PAGE 29
Time/Temp Display inoperative REFER TO PAGE 27
From S/N 2011383 and up REFER TO PAGE 29
Temp Display out or erratic REFER TO PAGE 27
From S/N 2011383 and up REFER TO PAGE 29
Содержание IMPINGER 1100
Страница 8: ...Impinger II 1100 Series Service Manual Domestic 8 SCHEMATIC 1100 1101 ...
Страница 9: ...Impinger II 1100 Series Service Manual Domestic 9 SCHEMATIC 1102 1103 ...
Страница 10: ...Impinger II 1100 Series Service Manual Domestic 10 SCHEMATIC 1116 1117 S N 2011383 BELOW ...
Страница 11: ...Impinger II 1100 Series Service Manual Domestic 11 SCHEMATIC 1116 1117 S N 2011384 ABOVE ...
Страница 13: ...Impinger II 1100 Series Service Manual Domestic 13 SCHEMATIC 1130 1131 S N 2011384 ABOVE ...
Страница 14: ...Impinger II 1100 Series Service Manual Domestic 14 SCHEMATIC 1160 1161 S N 2011978 ABOVE ...
Страница 16: ...Impinger II 1100 Series Service Manual Domestic 16 SCHEMATIC 1132 1133 S N 2011384 ABOVE ...
Страница 17: ...Impinger II 1100 Series Service Manual Domestic 17 SCHEMATIC 1162 1163 S N 2011978 ABOVE ...
Страница 51: ...Impinger II 1100 Series Service Manual Domestic 51 BLOW UP GENERAL 1100 SERIES ...
Страница 55: ...Impinger II 1100 Series Service Manual Domestic 55 BLOW UP CONTROL COMPARTMENT FRONT 1116 1117 ...
Страница 65: ...Impinger II 1100 Series Service Manual Domestic 65 BLOW UP OVEN BACK ASSEMBLY 1100 SERIES ...
Страница 67: ...Impinger II 1100 Series Service Manual Domestic 67 BLOW UP GEARMOTOR ASSEMBLY 1100 SERIES ...
Страница 69: ...Impinger II 1100 Series Service Manual Domestic 69 BLOW UP CONVEYOR DOOR 1100 SERIES ...
Страница 71: ...Impinger II 1100 Series Service Manual Domestic 71 This page intentionally left blank ...
Страница 72: ...Impinger II 1100 Series Service Manual Domestic 72 ...