P05 PAN-axis middle position
With this function the
PAN-axis
middle position can be set.
Please read first chapter
PAN-axis moving range, page 15
.
Range of values:
2000..2100 unit (value of the absolute value device)
Recommended value:
2048. So that the spigots stay the same way as the yoke
Operation:
depress You are now on menu level. The last adjusted menu
point is displayed, e.g.:
Menu P01:
DMX address motoryoke
depress ... until Menu P05 is displayed.
depress The second line displays the currently adjusted value.
depress Adjust the desired value.
depress You are back on menu level.
depress The equipment is ready for operation.
Caution !!
Check the
entire moving
range of the lamp:
The lamp-manufacturer specify
minimum distances
to inflammable materials. Never fall
below the minimum distance in no position of the lamp!
Make sure that a mounted lamp will never shine
onto
the motoryoke
Make sure that no cable will be
broken
,
bended
,
stretched
or
damaged
anyhow by
reason of turning the motoryoke!