P14 Focus / rotation 0%-value
At this point the
position of the focus or the rotation unit for 0% DMX-value
can be set.
This function is only available, when focus/rotation module is switched on. This can be
done in menu
P02, rotation module ON/OFF, page 21.
Caution!
The 0%-value must be
smaller
than the the 100%-value! (P14 smaller than P15)
You have the possibility to set this value automatically. When depressing the menu button
again (see operation), the Focus unit moves to the mechanical stop and stops moving.
Now the focus unit should be moved 20 values by depressing the UP-key. This is to avoid
a crash during normal moving.
Caution!
Do
not
use the auto-adjustment function with the rotation!
Range of values:
10..4000 units (value of the absolute value device)
Operation:
depress You are now on menu level. The last adjusted menu
point is displayed, e.g.:
Menu P01:
DMX address motoryoke
depress ... until Menu P14 is displayed.
depress The second line displays the currently adjusted value.
depress Adjust the desired value, rotation is moving to this position
depress You are back on menu level.
depress The equipment is ready for operation.
Motoryoke YipMan1 V4.58 Rev 1.00 27
Menü
Menü
Ok
Ok