P11 PAN-axis moving range
At this point the
PAN-axis moving range
can be programmed. The moving range has as
reference point the PAN-axis middle position which can be set in P05,
PAN-axis middle
position, page 22
. For example: If this menu is programmed to 90°, the motoryoke moves
90° to the left
and
90° to right from middle position.
Before programming this point read chapter
PAN-axis moving range, page 15
and
P05
PAN-axis middle position, page 22
!
Range of values:
10 - 190 degree
Recommended value:
45 - 180 degree
Operation:
depress You are now on menu level. The last adjusted menu
point is displayed, e.g.:
Menu P01:
DMX address motoryoke
depress ... until Menu P11 is displayed.
depress The second line displays the currently adjusted value.
depress Adjust the desired value.
depress You are back on menu level.
depress The equipment is ready for operation.
Caution !!
Check the
entire moving
range of the lamp:
The lamp-manufacturer specify
minimum distances
to inflammable materials. Never fall
below the minimum distance in no position of the lamp!
Make sure that a mounted lamp will never shine
onto
the motoryoke
Make sure that no cable will be
broken
,
bended
,
stretched
or
damaged
anyhow by
reason of turning the motoryoke!
24
Motoryoke YipMan1 V4.58 Rev 1.00
Menü
Menü
Ok
Ok