![LG Multi V 5 Скачать руководство пользователя страница 118](http://html.mh-extra.com/html/lg/multi-v-5/multi-v-5_service-manual_1892770118.webp)
118
MUL
TI V 5 Outdoor Unit Service Manual
Due to our policy of continuous product innovation, some specifications may change without notification.
©LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG” is a registered trademark of LG Corp.
Checking the Electronic Expansion Valves, continued.
Component
Problem
Diagnosis
Solution
Indoor Unit /
Outdoor Unit
EEV locks up.
Check for a locked EEV, if the system is in a no-load state,
if the driving motor is rotating, and a clicking sound can be
heard.
Replace EEV.
Incomplete EEV connection or
assembly.
1. Check if the pin is fully inserted into the connector.
2. Check the color of the wiring; verify that the correct wire is
connected.
3. Remove the connector from the control board, and test the
connection.
Find the incomplete
connection or assembly,
and service accordingly.
Indoor Unit
EEV is closed, but valve is
leaking.
1. Operate one indoor unit in fan mode, and then operate
another indoor unit in cooling mode.
2. Check the liquid piping temperature of the indoor unit in fan
mode (through the outdoor unit control board).
3. Check if the fan is rotating and the EEV is closed. If there
is a leak, the liquid piping temperature at the indoor unit in fan
mode will be low.
If the measured temperature is very low when compared to
the suction temperature (that is displayed at the remote
controller), then the EEV is not fully closed.
If the amount that
is leaking is excessive,
replace the EEV.
EEV motor coil has shorted out or
has disconnected.
Check the resistance between the coil terminals (red-white,
red-orange, brown-yellow, brown-blue).
Replace EEV.
Outdoor Unit
1. Check the resistance between the coil terminals at the
subcooling EEV (red-white, red-yellow, red-orange, red-blue).
,IWKHPHDVXUHGUHVLVWDQFHYDOXHLVLQȍDW)WKHQ
the EEV is normal.
Replace EEV coil.
1. Check the resistance between the coil terminals at the main /
IV EEV (red-white, red-orange, brown-yellow, brown-blue).
,IWKHPHDVXUHGUHVLVWDQFHYDOXHLVȍWKHQWKH
EEV is normal.
Replace EEV.
CHECKING THE ELECTRONIC
EXPANSION VALVES