Equipment overview
< Exterior view of inverter main components >
a
Inverter Power Box - This is the inverter section of the assembly. This section is sealed at the
factory and there are no user-serviceable parts inside. All wiring to install the inverter is done in
the wiring box.
b
Wiring Box Cover - This is the cover for the wiring compartment. Please note the DC disconnect
must be in the OFF position before this cover can be removed.
c
LED Lights - The five LED lights indicate errors or status.
d
Mounting Plate - The inverter comes with a mounting plate that allows easy assembly of the
inverter to a wall.
e
Wiring Box - This is the compartment where all the wiring for the inverter inputs and outputs
plus the RS485 communication are done.
f
Conduit Plugs - There are 5 - 3/4“ conduit openings and 2 - 1/2“ conduit openings. Each
conduit opening comes fitted with a conduit plug that should be removed before installing
conduit fittings. Conduit fittings need to be watertight with either NEMA 4, 4X, 6, or 6X rated,
and an insulated type is preferred.
y
The DC Disconnect is shown with the lock in the OFF position. There is an opening on the
disconnect where a padlock can be attached.