Operation
53
Oper
ation
3
The LEDs indicate the operational status of the inverter
Message
Category
LED Signals
Message Explanation
Example
LED
Color
Status
Behavior
OPER LED
Normal operation
OPER
Green
<ON>
constantly on
The inverter feeds into the grid.
Sync.
OPER
Green
<BLINK>
or <ON>
Four LEDs form a
progress bar.
The inverter is synchronizing
with grid.
LED signals:
OPER LED is ON,
BAT LED is ON.
COMM LED Blinks
Message:
Synchronization progress is
50%-75%.
BAT
Green
<BLINK>
or <ON>
COMM Green
<BLINK>
or <ON>
INFO
Green
<BLINK>
or <ON>
Night mode
OPER
Green
<BLINK>
1s on, 4s off
Inverter is not producing or
absorbing power (absolute
power is smaller than 20W).
BAT LED
Battery fault
BAT
Red
<ON>
constantly on
Battery is in fault mode.
Battery comm. fail
BAT
Yellow
<ON>
constantly on
Battery communication timeout
Battery standby
BAT
Yellow
<BLINK>
1s on, 1s off
Battery is in standby mode
Battery low power BAT
Green
<BLINK>
1s on, 4s off
Absolute battery power is lower
than 50W
Battery normal
BAT
Green
<ON>
constantly on
Battery is in normal operation.
COMM LED
BLE fail
COMM Red
<ON>
constantly on
BLE is in fault mode
APP Connected
COMM Green
<ON>
constantly on
APP is connected
BLE is running
COMM Green
<BLINK>
0.2s on, 0.2s off
BLE is running, only BLINK for
about 5 cycles in one minute
XBee connected
COMM Green /
Yellow
<ON>
2s Green on, 2s
Yellow on
XBee is connected to Router
XBee running
COMM Green
<BLINK>
1s on, 1s off
XBee is running, searching for
network (XBee and Gateway
can’t be installed at the same
time)
Gateway running
COMM Green
<BLINK>
1s on, 1s off
Gateway is communicating with
PCS (XBee and Gateway can’t
be installed at the same time)