Getting Started
7
Getting Star
ted
1
DC 7.6kW
Main Panel
Protected
Sub-Panel
RS 485 communication
ATS
Fireman
switch
Main Load
Protected
Load
Energy Meter
Split phase
240V
3-String
RSD Box
AC Power
DC Power
Communication
Installation
By mobile app.
Main Panel
Protected
Sub-Panel
RS 485 communication
Not allowing PV usage during off-grid mode
※
A detailed description of the AC configuration allows PV usage during grid outage is provided in the appendix.
1)
2)
Protected
Load
Energy Meter
AC Power
DC Power
Communication
1) 2)
AC 5kW
Installation
By mobile app.
Existing Solar system Or LG AC Module
Auto-TX
Switch Box
Fireman
switch
Main Load
Split phase
240V
PV inverter
< System Overview >
PV modules
For the DC-coupled system, the PV modules work in MPPT mode or power reduction mode
according to system operational mode. The maximum number of PV strings is three. For the AC-
coupled system, there is the option to have no solar modules connected to the LG Electronics ESS
inverter at all, and the PV power option will be deactivated.
Battery Pack
The Battery Pack can store surplus energy generated from rooftop solar modules for use when
needed. When the sun has set, energy demand is high, or there is a black-out, you can use the
energy stored in your Energy Storage System to meet your energy needs at no extra cost. Unlike
a grid-tied solar system which automatically switches off, a battery storage system allows you to
keep generating and consuming energy when the grid goes down.
RSD
The RSD provides an automatic disconnect of residential or small commercial PV systems, fully
compliant with the Rapid Shutdown requirements of NEC 2014 Article 690.12.
Содержание A005KEEN261