LESsoft configuration software
Leuze electronic
LES 36
88
TNT
35/7-2
4
V
In Figure 9.10 there is a narrow object with
Current Hits
= 20 in the measurement range
of the LES. The object is considered to be not detected, the state of object detection in the
Edge Analysis Window Definitions
window ->
Analysis Window Definitions
is red (
not ok
).
Figure 9.10: Application example 3.2: width monitoring of cubic objects with object detection
In the
Edge Analysis Window Combination Tables
window, the additional object
detection is activated by selecting
+
under EAW1. The result for object detection is
not ok
(red state). The
Edge State
(AND combination of the results of edge and object detection)
is displayed red (
not ok
). The ascertained width of the object is 14.2mm (column
Edge1
-> line
Width (X)
).
Note!
For sensors with
analog output
,
a valid measurement value transmission for edges only
occurs at the analog output if the
Edge Status
is
ok
In the case of sensors with
digital switching outputs
at X3 (LES 36/VC6, LES 36 HI/VC6),
the status of Edge 1 to 4 is signaled at outputs Out1 to Out4 (HIGH active).