Integration of the LES 36…/PB in the PROFIBUS
Leuze electronic
LES 36
117
TNT
35/7-2
4
V
11.3
General information about the GSD file
If the
LES 36…/PB
is operated in a PROFIBUS network, configuration can be performed
exclusively via the LESsoft configuration software. The functionality of the inputs/outputs of
the light section sensor to the control is defined via modules. Using a user-specific configu-
ration tool, the respective required modules are integrated and configured according to the
measurement application during PLC programming.
During operation of the light section sensor on the PROFIBUS, the functionality of the inputs/
outputs is assigned default values. If these values are not changed by the user, the device
operates with the default setting set by Leuze electronic on delivery. Please refer to the
following module descriptions for the default settings of the device.
Note!
At least one module from the GSD file must be activated in the configuration tool of the con-
trol, usually
module M1, M2 or M3
.
Note!
Some controls make available a so-called "universal module". This module must not be acti-
vated for the LES 36…/PB.
Attention!
The device makes available a PROFIBUS interface and an Ethernet interface. Both inter-
faces can be operated in parallel.
Note!
For test purposes, parameters can be changed on a LES 36…/PB operated on PROFIBUS.
At this time, object detection is not possible on PROFIBUS.
Note!
All input and output modules described in this documentation are described
from the view-
point of the control
:
Inputs (I) described are inputs of the control.
Outputs (O) described are outputs of the control.
Parameters (P) described are parameters of the GSD file in the control.
Note!
The current version of the GSD file
LEUZE403.GSD
for the LES 36…/PB can be found on
the Leuze website