Operating principle
Leuze electronic
LES 36
18
TNT
35/7-2
4
V
Possible measure against laser occlusion
• Using multiple Light section sensors with rotated
viewing direction. In the application example on
the right you can clearly see that the fields of vision
of the three sensors complement each other and
merge. The first of the sensors is operated as a
master, the two others are cascaded (see "Cas-
cading" on page 24). This reliably prevents mutual
interference of the sensors.
Possible measures against receiver occlusion
• Alignment of the measurement objects so that all profile data to be measured can be
seen by the receiver.
Or:
• Installing a second sensor featuring a viewing
direction rotated by 180° about the z-axis so that
the objects can be viewed from 2 sides.
In the example to the right, the left sensor detects
the profile data on the left side of the product, and
the right sensor the profile data on the right side.
In this situation the second sensor is then cas-
caded. "Cascading" on page 24.
Y