Installation and mounting
Leuze electronic GmbH + Co. KG
AMS 348
i
SSI
19
TNT
35/7-2
4V
If you have any questions concerning your shipment, please contact your supplier or your
local Leuze sales office.
Observe the applicable local regulations when disposing of the packaging materials.
5.2
Mounting the AMS 348
i
SSI
Figure 5.2: Mounting the device
The AMS 348
i
SSI and the corresponding reflector are mounted on two mutually opposing,
plane-parallel, flat walls or system parts. For error-free position measurement, there must
be an unobstructed line-of-sight between the AMS 348
i
SSI and the reflector.
Use M5 screws to fasten the laser measurement system. Secure the screws with a lock
washer to protect against loosening caused by vibrations.
A
M5 screw for align
-
ment
B
Knurled nut and nut
with WAF4 hexagon
socket for securing
C
Optical axis
A
B
A
C