PROFINET interface
98
AMS 348
i
SSI
Leuze electronic GmbH + Co. KG
9.9.3.17 Module 17: SSI interface
PROFINET module identifier
Module ID
1017
Submodule ID
1
Description
The module defines the parameters for the SSI interface.
Attention!
The SSI interface can only represent positive distance values. If negative output values are
ascertained due to the offset or counting direction, a zero value is output at the SSI interface!
In the event of a number overflow, all data bits are set to "1".
The Unit, Offset and Counting direction parameters of module 1 also apply to the SSI inter
-
face.
Note!
If the SSI interface is not configured via module 17 (SSI interface) in PROFINET operation,
the SSI interface is operated with the default parameters.
If the SSI interface is operated without PROFINET (PROFINET OFF/SSI ON), configuration
is performed via the display.