Installation and mounting
Leuze electronic GmbH + Co. KG
AMS 348
i
SSI
23
TNT
35/7-2
4V
The reflectors are mounted stationary and in parallel on one plane.
Both AMS 348
i
SSI move independently of one another at different or the same dis
-
tances to the reflectors.
Measurement distance up to 120m: minimum parallel spacing X
≥
600mm
Measurement distance up to 200m: minimum parallel spacing X
≥
750mm
Measurement distance up to 300m: minimum parallel spacing X
≥
750mm
Note!
Please note that when the
AMS 348
i
SSI are mounted in a mobile manner, travel tolerances
could cause the two laser light spots to move towards each other.
Take the travel tolerances of the vehicle into account when defining the parallel spacing of
adjacent
AMS 348
i
SSI.
5.2.3
Parallel mounting of AMS 348
i
SSI and DDLS optical data transmission
The optical data transceivers of the DDLS series and the AMS 348
i
SSI do not interfere with
one another. Depending on the size of the used reflector, the DDLS can be mounted with a
minimum parallel spacing of 100mm to the AMS 348
i
SSI. The parallel spacing is indepen
-
dent of the distance.