Technical data
Leuze electronic GmbH + Co. KG
AMS 348
i
SSI
15
TNT
35/7-2
4V
The AMS 348
i
SSI is designed in accordance with protection class III for
supply with PELV (protective extra-low voltage).
Display
Monochromatic graphical display, 128 x 64 pixels
LED
4 LEDs, 2 of which are used to indicate the state of the PROFINET
connection
Inputs/outputs
Quantity
Input
Output
2, programmable
Protected against polarity reversal
Max. 60 mA, short-circuit-proof
Mechanical data
Housing
Diecast zinc/aluminum
Optics
Glass
Weight
Approx. 2.45 kg
Degree of protection
IP 65 acc. to EN 60529
3)
Environmental conditions
Operating temperature
without device heating
with device heating
-5°C … +50°C
-
30°C … +50°C
4)
Storage temperature
-
30°C … +70°C
Air humidity
Max. 90% rel. humidity, non-condensing
MTTF
31 years (at 25 °C)
5)
Mechanical/electrical loading capacity
Vibration
Acc. to EN 60068
-
2
-
6
Noise
Acc. to EN 60060
-
2
-
64
Shock
Acc. to EN 60068
-
2
-
27
EMC
Acc. to EN 61000
-
6
-
2 and EN 61000
-
6
-
4
6)
1) Statistical error: 1 sigma; minimum switch-on time: 2min.
2) For UL applications: only for use in "Class 2" circuits according to NEC.
3) With screwed-on M12 connectors or mounted caps.
4) With devices with heating, the switch on/off area of the internal heating can be extended to prevent
condensation from forming. Total prevention of condensation cannot be guaranteed due to the limited
heating capacity of the AMS 348
i
SSI.
5) We reserve the right to make changes. (Value is updated at regular intervals.)
6) This is a Class A product. In a domestic environment this product may cause radio interference, in which
case the operator may be required to take adequate measures.