PROFINET interface
Leuze electronic GmbH + Co. KG
AMS 348
i
SSI
89
TNT
35/7-2
4V
Parameter
Input data
Output data
None
Parameter
Description
Rel.
addr
.
Data
type
Value
Default Unit
CR to
module
Metr. Inch
Velocity
resolution
The parameter specifies the reso
-
lution for the velocity value.
0.0
…
0.2
Bit
001=1: 1
010=2: 10
011=3: 100
100=4: 1000
101 = 5: free resolution
1
mm/s
(in/
100)
/s
20b
Averaging
The parameter specifies the
response time (averaging time) of
the calculated velocity values
0.3
…
0.5
Bit
000=0: 2
001=1: 4
010=2: 8
011=3: 16
100=4: 32
101=5: 64
110=6: 128
3
ms
–
Parameter length: 2 bytes
~
Ä
Input data
Description
Rel.
addr
.
Data
type
Value
Default Unit
CR to
module
Metr. Inch
Velocity
Current velocity.
0
sign
32 bit
-999999 … +999999
0
Scaled
–
Input data length: 4 bytes consistently
Å