PROFINET interface
Leuze electronic GmbH + Co. KG
AMS 348
i
SSI
87
TNT
35/7-2
4V
9.9.3.9 Module 9: Error handling procedures
PROFINET module identifier
Module ID
1009
Submodule ID
1
Description
The module makes parameters available to handle any errors should they occur.
In the event of a temporary error in the value/velocity calculation (e.g. plausibility error caused
by light beam interruption), the laser measurement system transmits the last valid measure
-
ment value for a configured length of time xx.
If the configured time is exceeded, the error display or the error measurement value output
is activated.
Parameter
Parameter
Description
Rel.
addr.
Data
type
Value
Default Unit
CR to
module
Metr. Inch
Position
value in the
case of fai
-
lure
Specifies which position value is
to be output in the event of an
error after the position suppres
-
sion time has elapsed.
0.0
Bit
0: Last valid value
1: Zero
1
mm
in/
100
–
No function.
0.1
Bit
always 0
0
–
–
Suppress
position sta
-
tus
Specifies whether the PLB status
bit is set immediately in the event
of an error or if it is suppressed
for the configured position sup
-
pression time.
0.2
Bit
0: OFF
1: ON
1
–
–
Error delay
(position)
Specifies in the event of an error
whether the position value imme
-
diately outputs the value of the
"Position value in the case of fail
-
ure" parameter or outputs the
last valid position value for the
duration of the configured "error
delay time".
0.3
Bit
0: OFF
1: ON
1
–
–
Error delay
time (posi
-
tion)
Errors which occur are sup
-
pressed for the configured time.
If no valid position value can be
ascertained during the config
-
ured time, the last valid position
value is output. If the error per
-
sists after the time elapses, the
value stored in the "Position
value in the case of failure"
parameter is output.
1…2 unsign
16 bit
100 … 1000
100
ms
–
Velocity in
the case of
failure
Specifies which velocity is to be
output in the event of an error
after the velocity suppression
time has elapsed.
3.0
Bit
0: Last valid value
1: Zero
1
–
–
No function.
3.1
Bit
always 0
0
–
–
Suppress
velocity sta
-
tus
Specifies whether the PLB status
bit is set immediately in the event
of an error or if it is suppressed
for the configured velocity sup
-
pression time.
3.2
Bit
0: OFF
1: ON
1
–
–
~
Ä
Å
Ç
É
Ñ