PROFINET interface
Leuze electronic GmbH + Co. KG
AMS 348
i
SSI
75
TNT
35/7-2
4V
9.9.3.1 Module 1: Position value
PROFINET module identifier
Module ID
1001
Submodule ID
1
Description
Outputs the current position value.
The parameters for sign, unit, resolution, counting direction and offset remain adjustable.
Parameter
Parameter
Description
Rel.
addr
.
Data
type
Value range
Default Unit
CR to
module
Metr. Inch
Sign
Output mode of the sign.
Sign affects position and velocity
output
0.0 Bit
0: Two's complement
1: Sign + magnitude
0
–
–
Unit
Selection of the unit
1)
.
The parameter applies to all val
-
ues with units. The parameter
applies to all interfaces.
0.1 Bit
0: metric
1: Inch (in)
0
–
–
Resolution
Resolution of the position value
Affects only the PROFINET out
-
put. The resolution has no effect
on:
- Static preset
- Dynamic preset
- Offset
0.2
…
0.4
Bit
001 = 1: 0.001
010 = 2: 0.01
011 = 3: 0.1
100 = 4: 1
101 = 5: 10
110 = 6: Free resolution
4
mm
in/100 20a
Counting
direction
Counting direction positive:
Counting direction negative:
The parameter applies to all inter
-
faces.
The counting direction changes
the sign during velocity measure
-
ment.
0.5 Bit
0: Positive
1: Negative
0
–
–
~
Ä
Å
Ç
0m
+100m
0m
-100m