Technical data
Rated data
Operation at rated mains voltage 400 V
4
30
EDS84ABD302 EN 4.0
Alternative DC supply
Basis of the data
Mains
Voltage
U
DC
[V]
Voltage range
U
DC
[V]
Frequency range
f [Hz]
2/PE DC
565
455 - 0 % ... 620 + 0 %
-
Type
Input current at I
aN
Output power
U, V, W
Motor power
4.pol. ASM
I
DC
[A]
S
aN
[kVA]
P
aN
[kW]
E84AVBxx3714
2.2
0.8
0.37
E84AVBxx5514
2.8
1.1
0.55
E84AVBxx7514
3.6
1.5
0.75
E84AVBxx1124
5.1
2.0
1.1
E84AVBxx1524
5.8
2.4
1.5
E84AVBxx2224
7.6
3.5
2.2
E84AVBxx3024
10.0
4.6
3.0