Braking operation
Braking operation with external brake resistor
Operation at rated mains voltage 500 V
8
97
EDS84ABD302 EN 4.0
8.3.2
Operation at rated mains voltage 500 V
Switching threshold V
BRmax
: 790 V, adjustable
R
Bmin
[
Ω
]
I
BRmax
[A]
P
BRmax
[kW]
I
BRd
[A]
P
Bd
[kW]
t
Z
[s]
t
on
[s]
t
fp
[s]
Type
E84AVBxx3714
390
2.0
1.6
2.0
1.6
-
∞
-
E84AVBxx5514
390
2.0
1.6
2.0
1.6
-
∞
-
E84AVBxx7514
390
2.0
1.6
2.0
1.6
-
∞
-
E84AVBxx1124
180
4.4
3.5
4.4
3.5
-
∞
-
E84AVBxx1524
180
4.4
3.5
4.4
3.5
-
∞
-
E84AVBxx2224
150
5.3
4.2
5.3
4.2
-
∞
-
E84AVBxx3024
100
7.9
6.2
7.9
6.2
-
∞
-
R
Bmin
Minimum brake resistance, nominal value ±10 %
I
BRmax
Peak current
P
BRmax
Peak braking power
I
BRd
Continuous current RMS - important for cable dimensioning
P
Bd
Continuous braking power
t
Z
Cycle time, periodic load change with running time and recovery time
t
on
Running time in a cycle without reducing the scanning ratio (
∞
= no time limit)
t
Z
- t
on
Recovery time
t
fp
Maximum running time without initial load and observing the recovery time