Technical data
Rated data
Overview
4
24
EDS84ABD302 EN 4.0
4.2
Rated data
4.2.1
Overview
Input data
Basis of the data
Mains
Voltage
U
LN
[V]
Voltage range
U
LN
[V]
Frequency range
f [Hz]
1/N/PE AC
230
180 - 0 % ... 264 + 0 %
45 - 0 % ... 65 + 0 %
3/PE AC
400
320 - 0 % ... 440 + 0 %
45 - 0 % ... 65 + 0 %
3/PE AC
500
400 - 0 % ... 550 + 0 %
45 - 0 % ... 65 + 0 %
Voltage
Frequency
Current [A]
Number of
phases
Type
[V]
[Hz]
max. +45 °C
c
max. +55 °C
c
E84AVBxx2512
230
50/60
3.4
2.6
1
E84AVBxx3712
230
50/60
5.1
3.8
1
E84AVBxx5512
230
50/60
6.7
5.0
1
E84AVBxx7512
230
50/60
8.8
6.6
1
E84AVBxx1122
230
50/60
12
9.0
1
E84AVBxx1522
230
50/60
13.7
10.3
1
E84AVBxx2222
230
50/60
22.0
18.4
1
E84AVBxx3714
400/500
50/60
1.8/1.5
1.4/1.1
3
E84AVBxx5514
400/500
50/60
2.3/2.0
1.7/1.5
3
E84AVBxx7514
400/500
50/60
3.2/2.7
2.4/2.0
3
E84AVBxx1124
400/500
50/60
4.2/3.6
3.2/2.7
3
E84AVBxx1524
400/500
50/60
4.7/4.1
3.5/3.1
3
E84AVBxx2224
400/500
50/60
6.2/5.4
4.7/4.1
3
E84AVBxx3024
400/500
50/60
10.2/7.8
7.7/5.9
3
c
Ambient temperature in the control cabinet, switching frequency 2 and 4 kHz, operation without mains choke