Electrical installation
Devices in the power range from 0.37 to 3 kW (3/PE AC 400 V)
Example circuits
6
66
EDS84ABD302 EN 4.0
6.4
Devices in the power range from 0.37 to 3 kW (3/PE AC 400 V)
6.4.1
Example circuits
3/PE AC 400 V/500 V
L1
L2
L3
N
PE
F1 … F3
K
Z
L2/N
E84AVBxxxxx ...
4
L1
U
V
W PE PE
M
3~
"
X105
+
X100
L3
X101
COM
"
"
-UG
+UG
X109
X13
"
I/O Shields
50
mA
S1
X4
3.3k
10
V
12
V
1k ... 10k
DO1 24E DI4 DI3 DI2 DI1 RFR 12I AR A1U
GND
DC 24 V
(+15.0 ... +30.0 V)
GND
GND
NO
3.3k
3.3k
3.3k
3.3k
>50k
PE
PE
BR
8400BLD025
Fig. 6-11
Wiring for controllers with 400-V/500-V mains connection
DO1
The digital output is not available for devices with nameplate data
E84AVBDxxxxSX0