Step 6.
Align the SAS/SATA adapter so that the keys align correctly with the connector on the system board.
Step 7.
Insert the SAS/SATA adapter in the dedicated connector on the system board or PCI riser-card
slots.
Attention:
Incomplete insertion might cause damage to the server or the adapter.
a.
Insert the SAS/SATA adapter into the RAID connector on the system board until it is firmly
seated. The retention brackets secure the SAS/SATA adapter in place when the adapter is
firmly seated into the connector.
Note:
Remove the PCI bracket that come with ServeRAID H1110, ServeRAID M1115, or
ServeRAID M5110 SAS/SATA adapter before installing a SAS/SATA adapter in the dedicated
connector on the system board.
Figure 41. ServeRAID adapter installation
b.
Insert the SAS/SATA adapter into the PCI riser cards (see “Replacing an adapter” on page 226).
56
System x3550 M4 Installation and Service Guide