![Lenovo x3550 M4 Скачать руководство пользователя страница 872](http://html.mh-extra.com/html/lenovo/x3550-m4/x3550-m4_installation-and-service-manual_203258872.webp)
–
–
•
408-901-000 : MLNX:MLNX_DiagnosticTestIBPort Test Failed
Port Test Failed.
Recoverable
No
Severity
Error
Serviceable
Yes
Automatically notify support
No
User Response
Complete the following steps:
1. Make sure that the physical link of the port under test in the active state and a subnet manager
running on the fabric to which the port is attached.
2. If these condition was met but the test keeps failing the port's adapter might be faulty.
3. Try replacing the adapter and repeating the test.
Related links
–
–
–
DSA memory isolation test results
The following messages can result when you run the memory isolation test.
Test results for the DSA memory isolation test
The following messages can result when you run the DSA memory isolation test.
•
201-000-000 : Standalone Memory Test Passed
Quick/Full Memory Test All CPUs Passed.
Recoverable
No
Severity
Event
Serviceable
No
858
System x3550 M4 Installation and Service Guide
Содержание x3550 M4
Страница 1: ...System x3550 M4 Installation and Service Guide Machine Type 7914 ...
Страница 6: ...iv System x3550 M4 Installation and Service Guide ...
Страница 178: ...164 System x3550 M4 Installation and Service Guide ...
Страница 322: ...308 System x3550 M4 Installation and Service Guide ...
Страница 828: ...814 System x3550 M4 Installation and Service Guide ...
Страница 986: ...972 System x3550 M4 Installation and Service Guide ...
Страница 990: ...976 System x3550 M4 Installation and Service Guide ...
Страница 1005: ......
Страница 1006: ......