![Lenovo x3550 M4 Скачать руководство пользователя страница 241](http://html.mh-extra.com/html/lenovo/x3550-m4/x3550-m4_installation-and-service-manual_203258241.webp)
• The server provides one internal SAS/SATA RAID connector and two PCI slots on the system board.
See “System-board optional-device connectors” on page 30 for the location of the internal SAS/SATA
RAID connector and riser-card slots. You can replace the ServeRAID SAS/SATA adapter with an
optional ServeRAID SAS/SATA adapter in the slot. For configuration information, see the ServeRAID
documentation at http://www.lenovo.com/support.
• Do not set the maximum digital video adapter resolution above 1600 x 1200 at 75 Hz for an LCD monitor.
This is the highest resolution that is supported for any add-on video adapter that you install in the server.
• Read the following table before installing memory modules when any Quadro adapters is installed.
Table 24. NVIDIA Quadro video adapter configurations
Description
Supported maximum total memory size
Quadro 600 adapter
128 GB
Quadro 2000 adapter
512 GB
• Read the following table before installing NAND flash adapters.
Table 25. Adapter configurations
Description
Option part
number
PCI riser 1
PCI riser 2
Emulex dual-port 10GbE SFP+ embedded
adapter
00D8540
Six fans installed
required
1
Six fans installed
required
1
365 GB High IOPS MLC mono adapter
46C9078
Six fans installed
required
1
Six fans installed
required
1
785 GB High IOPS MLC mono adapter
46C9081
Six fans installed
required
1
Six fans installed
required
1
1.2 TB high IOPS MLC mono adapter
90Y4377
Six fans installed
required
1
Six fans installed
required
1
2.4 TB high IOPS MLC duo adapter
90Y4397
Not supported
Six fans installed
required
1
Flash Adapter F825 Enterprise Value
00AE861
Six fans installed
required
1
Six fans installed
required
1
Flash Adapter F1650 Enterprise Value
00AE864
Six fans installed
required
1
Six fans installed
required
1
300GB High IOPS MLC modular adapter
90Y4361
Six fans installed
required
1
Six fans installed
required
1
600GB High IOPS MLC modular adapter
90Y4365
Six fans installed
required
1
Six fans installed
required
1
800GB High IOPS MLC modular adapter
90Y4369
Six fans installed
required
1
Six fans installed
required
1
Flash Adapter F3200 Enterprise Value
00AE867
Not supported
Six fans installed
required
1
Qlogic 8200 dual-port 10GbE SFP+ VFA
90Y4600
Six fans installed
required
1
Six fans installed
required
1
ServeRAID M5120 SAS/SATA controller
81Y4478
Six fans installed
required
1
Six fans installed
required
1
ServeRAID M5225 SAS/SATA controller
00AE938
Not supported
Four fans installed
required
Solarflare SFN5162F midrange dual-port
10GbE SFP+ adapter
47C9952
Six fans installed
required
1
Six fans installed
required
1
Removing and replacing components
227
Содержание x3550 M4
Страница 1: ...System x3550 M4 Installation and Service Guide Machine Type 7914 ...
Страница 6: ...iv System x3550 M4 Installation and Service Guide ...
Страница 178: ...164 System x3550 M4 Installation and Service Guide ...
Страница 322: ...308 System x3550 M4 Installation and Service Guide ...
Страница 828: ...814 System x3550 M4 Installation and Service Guide ...
Страница 986: ...972 System x3550 M4 Installation and Service Guide ...
Страница 990: ...976 System x3550 M4 Installation and Service Guide ...
Страница 1005: ......
Страница 1006: ......