![Lenovo x3550 M4 Скачать руководство пользователя страница 402](http://html.mh-extra.com/html/lenovo/x3550-m4/x3550-m4_installation-and-service-manual_203258402.webp)
Warning
Serviceable
Yes
Automatically notify support
No
Alert Category
Warning - Temperature
SNMP Trap ID
12
CIM Information
Prefix:
PLAT
ID:
0490
User Response
1.
Reduce the temperature.
2. Check the server airflow. Make sure that nothing is blocking the air from coming into or
preventing the air from exiting the server.
•
80010701-2c01ffff : Numeric sensor [NumericSensorElementName] going high (upper non-critical)
has asserted. (Mezz Card Temp)
This message is for the use case when an implementation has detected an Upper Non-critical sensor
going high has asserted.
May also be shown as 800107012c01ffff or 0x800107012c01ffff
Severity
Warning
Serviceable
Yes
Automatically notify support
No
Alert Category
Warning - Temperature
SNMP Trap ID
12
CIM Information
Prefix:
PLAT
ID:
0490
User Response
1.
Reduce the temperature.
2. Check the server airflow. Make sure that nothing is blocking the air from coming into or
preventing the air from exiting the server.
388
System x3550 M4 Installation and Service Guide
Содержание x3550 M4
Страница 1: ...System x3550 M4 Installation and Service Guide Machine Type 7914 ...
Страница 6: ...iv System x3550 M4 Installation and Service Guide ...
Страница 178: ...164 System x3550 M4 Installation and Service Guide ...
Страница 322: ...308 System x3550 M4 Installation and Service Guide ...
Страница 828: ...814 System x3550 M4 Installation and Service Guide ...
Страница 986: ...972 System x3550 M4 Installation and Service Guide ...
Страница 990: ...976 System x3550 M4 Installation and Service Guide ...
Страница 1005: ......
Страница 1006: ......