80
NE0152T Installation Guide
Out-of-Band Management Interface Configuration
Complete the following steps to configure an out-of-band management IP address
and a default gateway:
1.
Log onto the switch using the serial console port or management port on the
NE0152T front panel.
2.
Enter the management interface configuration mode:
3.
Configure an IP address and subnet mask:
4.
Configure the out-of-band default gateway:
In-Band Management Interface Configuration
Complete the following steps to configure an in-band management IP address over
an SVI interface and an associated default gateway:
1.
Log onto the switch using the serial console port or management port on the
NE0152T front panel.
2.
Enter the SVI interface configuration mode:
3.
Configure the in-band management IP address:
4.
Configure the in-band default gateway:
NE0152T>
enable
NE0152T#
configure [terminal]
NE0152T(config)#
interface mgmt 0
NE0152T(config-if)#
NE0152T(config-if)#
ip address 10.254.87.6/24
NE0152T(config-if)#
exit
NE0152T(config)#
NE0152T(config)#
vrf context management
NE0152T(config-vrf)#
ip route 0.0.0.0/0 205.21.17.1
NE0152T(config-vrf)#
exit
NE0152T(config)#
NE0152T>
enable
NE0152T#
configure [terminal]
NE0152T(config)#
NE0152T(config)#
interface vlan 1
NE0152T(config-if)#
ip address 10.254.87.6/24
NE0152T(config-if)#
exit
NE0152T(config)#
NE0152T(config)#
ip route 0.0.0.0/0 205.21.17.1
Содержание ThinkSystem NE0152T
Страница 1: ...Lenovo ThinkSystem NE0152T RackSwitch Installation Guide For Lenovo Cloud Network Operating System ...
Страница 6: ...6 Lenovo NE0152T Installation Guide ...
Страница 14: ...14 NE0152T Installation Guide ...
Страница 19: ... Copyright Lenovo 2018 19 Chapter 2 Switch Components This chapter describes the NE0152T hardware components ...
Страница 30: ...30 NE0152T Installation Guide ...
Страница 72: ...72 NE0152T Installation Guide ...
Страница 84: ...84 NE0152T Installation Guide ...
Страница 90: ...90 NE0152T Installation Guide ...
Страница 110: ...110 NE0152T Installation Guide ...