“Removing a hot-swap drive” on page 77
•
“Installing a hot-swap drive” on page 78
The EMI integrity and cooling of the server are protected by having all drive bays covered or occupied. The
number of the installed drives in your server varies depending on the server model. The vacant bays are
either covered by an EMI-protective panel or occupied by dummy trays. When installing a drive, save the
removed dummy tray in case that you later remove the drive and need the dummy tray to cover the place.
Attention:
An unoccupied drive bay without any other protection might impact the EMI integrity and cooling
of the server, which might result in overheating or component damage. To maintain the EMI integrity and
cooling of the server, install a new drive as soon as you remove the failing one or the dummy tray.
Hot-swap drive installation rules
• When you install drives, follow the order of the drive bay numbers. See “Front view of the server” on
page 14 to locate the drive bays in your server.
• For RAID configuration, the drives must be the same type with the same capacity if they are within a single
RAID array. For more information, see “Configuring RAID” on page 47.
Removing a hot-swap drive
To remove a hot-swap drive, do the following:
1. Use the front door key to unlock the front door (available on some models), and then open the front door.
2. Locate the drive you want to remove and press the release button
1
to open the handle of the drive.
1
Figure 45. Opening the handle of a drive
.
77
Содержание ThinkServer TS460
Страница 1: ...ThinkServer TS460 User Guide and Hardware Maintenance Manual Machine Types 70TQ 70TR 70TS and 70TT ...
Страница 14: ...xii ThinkServer TS460 User Guide and Hardware Maintenance Manual ...
Страница 18: ...4 ThinkServer TS460 User Guide and Hardware Maintenance Manual ...
Страница 52: ...38 ThinkServer TS460 User Guide and Hardware Maintenance Manual ...
Страница 68: ...54 ThinkServer TS460 User Guide and Hardware Maintenance Manual ...
Страница 138: ...124 ThinkServer TS460 User Guide and Hardware Maintenance Manual ...
Страница 144: ...130 ThinkServer TS460 User Guide and Hardware Maintenance Manual ...
Страница 148: ...134 ThinkServer TS460 User Guide and Hardware Maintenance Manual ...
Страница 159: ...Taiwan BSMI RoHS declaration Appendix C Restriction of Hazardous Substances RoHS Directive 145 ...
Страница 160: ...146 ThinkServer TS460 User Guide and Hardware Maintenance Manual ...
Страница 171: ......
Страница 172: ......