3. Press the two tabs on the intrusion switch towards each other and carefully pull out the intrusion switch
at the same time to remove it from the frame.
Figure 58. Removing the intrusion switch
Installing the intrusion switch
To install the intrusion switch, do the following:
1. Prepare your server and remove the server cover. See “Preparing your server in advance and removing
2. If needed, remove the old intrusion switch. See “Removing the intrusion switch” on page 87.
3. Insert the cable of the new intrusion switch and then the tab on the intrusion switch frame into the
corresponding hole in the chassis. Then, push the intrusion switch in until it is securely seated.
Figure 59. Installing the intrusion switch
4. Connect the cable of the new intrusion switch to the branch connector on the front panel connector 2
that is connected to the system board. See “System board components” on page 33.
Front panel board assembly
•
“Removing the front panel board assembly” on page 88
•
“Installing the front panel board assembly” on page 89
Note:
The front panel board assembly is sensitive to ESD. Ensure that you read and understand “Handling
static-sensitive devices” on page 56 first and carefully perform the operation.
Removing the front panel board assembly
To remove the front panel board assembly, do the following:
1. Prepare your server and remove the server cover. See “Preparing your server in advance and removing
2. Remove the front bezel. See “Removing the front bezel” on page 59.
88
ThinkServer TS460 User Guide and Hardware Maintenance Manual
Содержание ThinkServer TS460
Страница 1: ...ThinkServer TS460 User Guide and Hardware Maintenance Manual Machine Types 70TQ 70TR 70TS and 70TT ...
Страница 14: ...xii ThinkServer TS460 User Guide and Hardware Maintenance Manual ...
Страница 18: ...4 ThinkServer TS460 User Guide and Hardware Maintenance Manual ...
Страница 52: ...38 ThinkServer TS460 User Guide and Hardware Maintenance Manual ...
Страница 68: ...54 ThinkServer TS460 User Guide and Hardware Maintenance Manual ...
Страница 138: ...124 ThinkServer TS460 User Guide and Hardware Maintenance Manual ...
Страница 144: ...130 ThinkServer TS460 User Guide and Hardware Maintenance Manual ...
Страница 148: ...134 ThinkServer TS460 User Guide and Hardware Maintenance Manual ...
Страница 159: ...Taiwan BSMI RoHS declaration Appendix C Restriction of Hazardous Substances RoHS Directive 145 ...
Страница 160: ...146 ThinkServer TS460 User Guide and Hardware Maintenance Manual ...
Страница 171: ......
Страница 172: ......