1. Touch the static-protective package that contains the new hot-swap redundant power supply to any
unpainted surface on the outside of the server. Then, take the new hot-swap redundant power supply
out of the package.
2. If you are installing a power supply, locate the bay for the power supply in the rear of your server.
Insert your index finger and thumb into the holes in the metal shield that protects the bay and pull the
shield out of the chassis. Store the shield in case that you later remove the power supply and need
the shield to cover the bay.
Figure 73. Removing the protective shield for the power supply bay
3. Note the orientation of the new hot-swap redundant power supply and then slide the new hot-swap
redundant power supply into the chassis until it snaps into position.