8. Align the screw holes in the drive adapter and the 2.5-inch drive with the corresponding holes in the drive
bracket. Then, install the five screws to secure the drive adapter and the 2.5-inch drive to the bracket.
Figure 89. Installing the screws to secure the drive adapter and the 2.5-inch drive to the bracket
9. Slide the bracket with the 2.5-inch drive into the drive bay from the front until it snaps into position
and then completely close the handle.
Figure 90. Installing the bracket with the 2.5-inch drive
10. Check the drive status LEDs to ensure that the 2.5-inch drive is operating correctly. You might have to
restart the server for the newly installed 2.5-inch drive to be recognized. See
LEDs” on page 38. If the 2.5-inch drive is faulty, reinstall or replace it until it is operating correctly.
11. Save the removed dummy hard-disk-drive tray in case that you later remove the 2.5-inch drive and need
a dummy tray to cover the drive bay.
What to do next:
• To work with another piece of hardware, go to the appropriate section.
• To configure RAID, go to “Configuring RAID” on page 50.
• To complete the installation, go to “Completing the parts replacement” on page 142.
118
ThinkServer RD350G User Guide and Hardware Maintenance Manual
Содержание ThinkServer RD350G
Страница 14: ...xii ThinkServer RD350G User Guide and Hardware Maintenance Manual ...
Страница 18: ...4 ThinkServer RD350G User Guide and Hardware Maintenance Manual ...
Страница 20: ...6 ThinkServer RD350G User Guide and Hardware Maintenance Manual ...
Страница 54: ...40 ThinkServer RD350G User Guide and Hardware Maintenance Manual ...
Страница 68: ...54 ThinkServer RD350G User Guide and Hardware Maintenance Manual ...
Страница 168: ...154 ThinkServer RD350G User Guide and Hardware Maintenance Manual ...
Страница 180: ...166 ThinkServer RD350G User Guide and Hardware Maintenance Manual ...
Страница 185: ......
Страница 186: ...Lenovo ...