10. Note the orientation of the new backplane. Ensure that the small hooks
1
on the chassis pass through
the corresponding holes in the new backplane. Then, carefully press the new backplane straight down
so that it is secured by the latches
2
on the backplane.
Figure 101. Installing the hot-swap hard-disk-drive backplane
11. Reinstall all the hot-swap hard disk drives and dummy trays (if any) on the backplane. See
swap hard disk drive” on page 109.
12. Refer to your note to reconnect the cables to the backplane.
13. If you are instructed to return the old hot-swap hard-disk-drive backplane, follow all packaging
instructions and use any packaging materials that are supplied to you for shipping.
What to do next:
• To work with another piece of hardware, go to the appropriate section.
• To complete the replacement, go to “Completing the parts replacement” on page 142.
Replacing the easy-swap-drive module
Before you begin, print all the related instructions or ensure that you can view the PDF version on another
computer for reference.
Notes:
• The easy-swap-drive module is sensitive to ESD. Ensure that you read and understand “Handling
sensitive devices” on page 56 first and carefully perform the operation.
• Depending on the model, your server might look slightly different from the illustrations in this topic.
To replace the easy-swap-drive module, do the following:
1. Remove all external media from the drives and turn off all attached devices and the server. Then,
disconnect all power cords from electrical outlets and disconnect all cables that are connected to
the server.
“Removing or extending the server from the rack cabinet” on page 57.
3. Remove the server cover. See
“Removing the server cover” on page 57.
4. Remove the cooling shroud. See
“Removing and reinstalling the cooling shroud” on page 60.
126
ThinkServer RD350G User Guide and Hardware Maintenance Manual
your
eading and
Содержание ThinkServer RD350G
Страница 14: ...xii ThinkServer RD350G User Guide and Hardware Maintenance Manual ...
Страница 18: ...4 ThinkServer RD350G User Guide and Hardware Maintenance Manual ...
Страница 20: ...6 ThinkServer RD350G User Guide and Hardware Maintenance Manual ...
Страница 54: ...40 ThinkServer RD350G User Guide and Hardware Maintenance Manual ...
Страница 68: ...54 ThinkServer RD350G User Guide and Hardware Maintenance Manual ...
Страница 168: ...154 ThinkServer RD350G User Guide and Hardware Maintenance Manual ...
Страница 180: ...166 ThinkServer RD350G User Guide and Hardware Maintenance Manual ...
Страница 185: ......
Страница 186: ...Lenovo ...