2
3
3
2
1
Thumb screws
Pins
Figure 43. Hot-swap hard disk drive backplane installation
Step 3.
Reinstall the hard disk drives and filler panels (see “Installing a hot-swap hard disk drive” on
page 91).
Step 4.
Reconnect all cables that you removed from the hard disk drive backplane (see “Internal cable
routing and connectors” on page 144).
Step 5.
Reinstall the fan cage cover (see “Installing the fan cage cover” on page 83).
1. Install the server into the rack enclosure and push the server into the rack until it clicks into place.
2. Reconnect the power cords and any cables that you removed.
3. Turn on the peripheral devices and the server.
Removing an adapter
Use this information to remove an adapter.
Read the safety information in “Safety” on page v and “Installation guidelines” on page 75.
If you are replacing a server component or installing an optional device in the server, you need to take
out the node out from the rack enclosure, turn off the server and peripheral devices, and disconnect all
external cables.
To remove an adapter, complete the following steps.
Step 1.
Remove the compute node (see “Removing a compute node from a chassis” on page 77).
Step 2.
Remove the PCI riser-card assembly (see “Removing the PCI riser-card assembly” on page 117).
Step 3.
Disconnect the cables from the adapter if any.
Step 4.
Place the PCI riser-card assembly on a flat, static-protective surface.
Step 5.
Remove the screw.
108
Lenovo ThinkServer sd350 Server Type 5493, Lenovo ThinkServer n400 Enclosure Type 5495Installation and Service Guide
Содержание ThinkServer n400
Страница 5: ...Taiwan BSMI RoHS declaration 182 Index 183 Copyright Lenovo iii ...
Страница 184: ...168 Lenovo ThinkServer sd350 Server Type 5493 Lenovo ThinkServer n400 Enclosure Type 5495Installation and Service Guide ...
Страница 186: ...170 Lenovo ThinkServer sd350 Server Type 5493 Lenovo ThinkServer n400 Enclosure Type 5495Installation and Service Guide ...
Страница 190: ...174 Lenovo ThinkServer sd350 Server Type 5493 Lenovo ThinkServer n400 Enclosure Type 5495Installation and Service Guide ...
Страница 205: ......