0B010BAB
Sensor Type: Other
Units-based sensor
Event Severity: Critical
Description: Upper
Non-Recoverable - Going
High - Asserted
HDD backplane
power consumption
is too high
1. Check the Lenovo support website for an
applicable tip or firmware update that applies
to this error. 2. Contact your Lenovo service
representative for support
0B0109AB
HDD_BP_Power
Sensor Type: Other
Units-based sensor
Event Severity: Critical
Description: Upper
Critical - Going High -
Asserted
HDD backplane
power consumption
is too high
1. Check the Lenovo support website for an
applicable tip or firmware update that applies
to this error. 2. Contact your Lenovo service
representative for support
160901C0 BMC_Boot_Up
Sensor Type:
Microcontroller /
Coprocessor Event
Severity: Info Description:
Device Enabled -
Asserted
BMC boot up
successfully.
It is just an information. Users don't need to
do anything.
226F00C1
Sensor Type: System
ACPI Power Event
Severity: Info Description:
S0/G0 'Working -
Asserted
The system is under
S0 state.
It is just an information. Users don't need to
do anything.
226F05C1
ACPI_PWR_Status
Sensor Type: System
ACPI Power Event
Severity: Info Description:
S4/S5 Soft-Off, Particular
S4/S5 State Cannot Be
Determined - Asserted
The system is under
S5 state.
It is just an information. Users don't need to
do anything.
146F00C2 Button_Status
Sensor Type: Button /
Switch Event Severity:
Info Description: Power
Button Pressed -
Asserted
Someone pressed
the power button
It is just an information. Users don't need to
do anything.
106F02C3
Sensor Type: Event
Logging Disabled Event
Severity: Info Description:
Log Area Reset/Cleared -
Asserted
The log area of SEL
is cleared.
It is just an information. Users don't need to
do anything.
106F05C3
SEL_Status
Sensor Type: Event
Logging Disabled
Event Severity: Info
Description: SEL Almost
Full - Asserted
The SEL is almost
full.
It is just an information. Users don't need to
do anything.
Appendix A. TMM error messages
163
Содержание ThinkServer n400
Страница 5: ...Taiwan BSMI RoHS declaration 182 Index 183 Copyright Lenovo iii ...
Страница 184: ...168 Lenovo ThinkServer sd350 Server Type 5493 Lenovo ThinkServer n400 Enclosure Type 5495Installation and Service Guide ...