0C0301D2 Mem_Therm_Trip
Sensor Type: Memory
Event Severity: Critical
Description: State
Asserted - Asserted
Memory
temperature is too
high. At the same
time, system will be
shutdown.
1. Check the Lenovo support website for an
applicable tip or firmware update that applies
to this error. 2. Check Fan status. if Fan
is broken, please replace the new Fan. 3.
Contact your Lenovo service representative
for support
196F01D3 PCH_Therm_Trip
Sensor Type: Chipset
Event Severity: Critical
Description: State
Asserted - Asserted
PCH temperature
is too high. At the
same time, system
will be shutdown.
1. Check contact condition of PCH heat
sink. 2. Check the Lenovo support website
for an applicable tip or firmware update that
applies to this error. 3. Check Fan status. if
Fan is broken, please replace the new Fan. 4.
Contact your Lenovo service representative
for support
0D6F01D4 HDD_Status
Sensor Type: Drive Slot
(Bay) Event Severity:
Critical Description: Drive
% Fault - Asserted
HDD % fault. (% =
HDD number)
1. Check Lenovo support site for an
applicable service bulletin or firmware update
that applies to this error. 2. Replace HDD. 3.
Contact your Lenovo service representative
for support.
1D6F02E0 BIOS_Boot_up
Sensor Type: System
Boot / Restart Initiated
Event Severity: Info
Description: Initiated By
Warm Reset - Asserted
BIOS boot up and
it's initiated by
warm reset.
It is just an information. Users don't need to
do anything.
0C6F00E2
Sensor Type: Memory
Event Severity: Critical
Description: Correctable
ECC - Asserted
A single bit error
is occurred In
memory. This error
will be repaired
automatically.
1. If the node has recently been installed,
moved, serviced, or upgraded, verify that the
DIMM is properly seated and visually verify
that there is no foreign material in any DIMM
connector on that memory channel. If either
of these conditions is found, correct and retry
with the same DIMM 2. If problem re-occurs
on the same DIMM connector, swap the
other DIMMs on the same memory channel
across channels one at a time to a different
memory channel or Processor. (check service
information for this product/Install guide for
population requirements for sparing/paring
modes). If problem follows a moved DIMM
to a different memory channel, replace that
DIMM.
0C6F01E2
Sensor Type: Memory
Event Severity:
Critical Description:
Uncorrectable ECC -
Asserted
A multiple bits
error is occurred in
memory. This error
will cause system
to be hang up.
1. Check the Lenovo support website for
an applicable service bulletin or firmware
update that applies to this memory error.
2. If the node has recently been installed,
moved, serviced, or upgraded, verify that the
DIMM is properly seated and visually verify
that there is no foreign material in any DIMM
connector on that memory channel. If either
of these conditions is found, correct and
retry with the same DIMM. 3. If no problem
is observed on the DIMM connectors and
the problem persists, replace the DIMM
identified by LightPath and/or event log
entry. 4. If problem re-occurs on the same
DIMM connector, swap the other DIMMs on
the same memory channel across channels
one at a time to a different memory channel
or Processor. (check service information
for this product/Install guide for population
Memory_Status
Appendix A. TMM error messages
165
Содержание ThinkServer n400
Страница 5: ...Taiwan BSMI RoHS declaration 182 Index 183 Copyright Lenovo iii ...
Страница 184: ...168 Lenovo ThinkServer sd350 Server Type 5493 Lenovo ThinkServer n400 Enclosure Type 5495Installation and Service Guide ...
Страница 186: ...170 Lenovo ThinkServer sd350 Server Type 5493 Lenovo ThinkServer n400 Enclosure Type 5495Installation and Service Guide ...
Страница 190: ...174 Lenovo ThinkServer sd350 Server Type 5493 Lenovo ThinkServer n400 Enclosure Type 5495Installation and Service Guide ...
Страница 205: ......
Страница 206: ...Part Number 00MV565 Printed in China 1P P N 00MV565 1P00MV565 ...