0B010796
Sensor Type: Other
Units-based sensor
Event Severity: Warning
Description: Upper
Non-Critical - Going High
- Asserted
Node output power
is too high
1. Check the Lenovo support website for an
applicable tip or firmware update that applies
to this error. 2. Contact your Lenovo service
representative for support
0B010B9A
Sensor Type: Other
Units-based sensor
Event Severity: Critical
Description: Upper
Non-Recoverable - Going
High - Asserted
CPU power
consumption is
too high
1. Check the Lenovo support website for an
applicable tip or firmware update that applies
to this error. 2. Contact your Lenovo service
representative for support
0B01099A
CPU_Power
Sensor Type: Other
Units-based sensor
Event Severity: Critical
Description: Upper
Critical - Going High -
Asserted
CPU power
consumption is
too high
1. Check the Lenovo support website for an
applicable tip or firmware update that applies
to this error. 2. Contact your Lenovo service
representative for support
0B010B9B
Sensor Type: Other
Units-based sensor
Event Severity: Critical
Description: Upper
Non-Recoverable - Going
High - Asserted
Memory power
consumption is too
high
1. Check the Lenovo support website for an
applicable tip or firmware update that applies
to this error. 2. Contact your Lenovo service
representative for support
0B01099B
Memory_Power
Sensor Type: Other
Units-based sensor
Event Severity: Critical
Description: Upper
Critical - Going High -
Asserted
Memory power
consumption is too
high
1. Check the Lenovo support website for an
applicable tip or firmware update that applies
to this error. 2. Contact your Lenovo service
representative for support
086F06A0 PSU_Mismatch
Sensor Type: Power
Supply Event Severity:
Critical Description:
Configuration Error -
Asserted
There are different
capacity or voltage
of PSUs that are
plugged in chassis.
1. See “Replacing a hot-swap power supply”
on page 99 to check if PSUs of different
voltage are installed 2. Check the Lenovo
support website for an applicable tip or
firmware update that applies to this error. 3.
Restart the server. 4. Suggest to use the
same type of PSUs. 5. Contact your Lenovo
service representative for support
086F01A1
086F01A2
Sensor Type: Power
Supply Event Severity:
Critical Description:
Power Supply Failure
Detected - Asserted
PSU is OCP or OVP
1. Check the Lenovo support website for an
applicable tip or firmware update that applies
to this error. 2. Contact your Lenovo service
representative for support
086F03A1
086F03A2
PSU%_Status (% =
PSU number)
Sensor Type: Power
Supply Event Severity:
Critical Description:
Power Supply Input Lost
(AC/DC) - Asserted
AC lost
1. Check the Lenovo support website for an
applicable tip or firmware update that applies
to this error. 2. Contact your Lenovo service
representative for support
Appendix A. TMM error messages
161
Содержание ThinkServer n400
Страница 5: ...Taiwan BSMI RoHS declaration 182 Index 183 Copyright Lenovo iii ...
Страница 184: ...168 Lenovo ThinkServer sd350 Server Type 5493 Lenovo ThinkServer n400 Enclosure Type 5495Installation and Service Guide ...
Страница 186: ...170 Lenovo ThinkServer sd350 Server Type 5493 Lenovo ThinkServer n400 Enclosure Type 5495Installation and Service Guide ...
Страница 190: ...174 Lenovo ThinkServer sd350 Server Type 5493 Lenovo ThinkServer n400 Enclosure Type 5495Installation and Service Guide ...
Страница 205: ......
Страница 206: ...Part Number 00MV565 Printed in China 1P P N 00MV565 1P00MV565 ...