000000
000000
000000
000000
000000
000000
000000
000000
000000
000000
000000
000000
00
00
000
00
00
0000000
0000000
0000000
0000000
0000000
0000000
Figure 60. SATADOM installation
Step 3.
Reinstall compute node (see “Installing a compute node in a chassis” on page 77).
1. Install the server into the rack enclosure and push the server into the rack until it clicks into place.
2. Reconnect any cables that you removed.
3. Turn on the peripheral devices and the server.
Removing and replacing FRUs
This section provides information for removing and replacing FRUs in the server.
FRUs must be installed only by trained service technicians.
The illustrations in this document might differ slightly from your hardware.
Removing the fan board
Use this information to remove the fan board from the server.
Read the safety information in “Safety” on page v and “Installation guidelines” on page 75.
If you are replacing a server component or installing an optional device in the server, you need to slide the
server out from the rack enclosure, turn off the server and peripheral devices, and disconnect the power
cords and all external cables.
To remove the fan board, complete the following steps.
Step 1.
Remove all the nodes (see “Removing a compute node from a chassis” on page 77).
Step 2.
Remove the fan cage cover (see “Removing the fan cage cover” on page 82).
Step 3.
Remove the system fan (see “Removing a system fan” on page 88).
Step 4.
Remove the fan cage (see “Removing the fan cage” on page 105).
Removing and replacing server components
121
Содержание ThinkServer n400
Страница 5: ...Taiwan BSMI RoHS declaration 182 Index 183 Copyright Lenovo iii ...
Страница 184: ...168 Lenovo ThinkServer sd350 Server Type 5493 Lenovo ThinkServer n400 Enclosure Type 5495Installation and Service Guide ...
Страница 186: ...170 Lenovo ThinkServer sd350 Server Type 5493 Lenovo ThinkServer n400 Enclosure Type 5495Installation and Service Guide ...
Страница 190: ...174 Lenovo ThinkServer sd350 Server Type 5493 Lenovo ThinkServer n400 Enclosure Type 5495Installation and Service Guide ...
Страница 205: ......
Страница 206: ...Part Number 00MV565 Printed in China 1P P N 00MV565 1P00MV565 ...