Figure 86. Power interface board installation
Step 3.
Tighten the power interface board with 5 6#32 screws.
Step 4.
Reinstall the cables on the power interface board.
Step 5.
Reinstall the fan cage (see “Replacing the fan cage” on page 105).
Step 6.
Reinstall the system fan (see “Replacing a system fan” on page 89).
Step 7.
Reinstall the system management board cover (see “Installing the system management board
cover” on page 85).
Step 8.
Reinstall the fan cage cover (see “Installing the fan cage cover” on page 83).
1. Install the server into the rack enclosure and push the server into the rack until it clicks into place.
2. Reconnect the power cords and any cables that you removed.
3. Turn on the peripheral devices and the server.
Removing the power interface board bracket
Use this information to remove the power interface board bracket from the server.
Read the safety information in “Safety” on page v and “Installation guidelines” on page 75.
If you are replacing a server component or installing an optional device in the server, you need to slide the
server out from the rack enclosure, turn off the server and peripheral devices, and disconnect the power
cords and all external cables.
To remove the power interface board bracket, complete the following steps.
Step 1.
Remove compute node #3 and #4.
Step 2.
Remove the fan cage cover (see “Removing the fan cage cover” on page 82).
Step 3.
Remove the system fan (see “Removing a system fan” on page 88).
Step 4.
Remove the fan cage (see “Removing the fan cage” on page 105).
Step 5.
Remove the power interface board (see “Removing the power interface board” on page 138).
140
Lenovo ThinkServer sd350 Server Type 5493, Lenovo ThinkServer n400 Enclosure Type 5495Installation and Service Guide
Содержание ThinkServer n400
Страница 5: ...Taiwan BSMI RoHS declaration 182 Index 183 Copyright Lenovo iii ...
Страница 184: ...168 Lenovo ThinkServer sd350 Server Type 5493 Lenovo ThinkServer n400 Enclosure Type 5495Installation and Service Guide ...
Страница 186: ...170 Lenovo ThinkServer sd350 Server Type 5493 Lenovo ThinkServer n400 Enclosure Type 5495Installation and Service Guide ...
Страница 190: ...174 Lenovo ThinkServer sd350 Server Type 5493 Lenovo ThinkServer n400 Enclosure Type 5495Installation and Service Guide ...
Страница 205: ......
Страница 206: ...Part Number 00MV565 Printed in China 1P P N 00MV565 1P00MV565 ...