628
G8332 Command Reference for ENOS 8.4
FCoE Forwarder Configuration
Use
the
following
commands
to
configure
FCoE
Forwarder
(FCF)
parameters.
The
following
table
describes
the
FCF
configuration
options.
Table 355.
FCoE
Configuration
Options
Command Syntax and Usage
fcf
area
size
<256
‐
4096>
vlan
<VLAN
ID
(2
‐
4094)>
Configures
area
width.
Command
mode
:
Global
configuration
fcf
concurrent
login
<1
‐
2048>
Configures
the
maximum
number
of
concurrent
FLOGI/FDISC
for
this
FCF.
The
default
setting
is
16
.
Command
mode
:
VLAN
no
fcf
concurrent
login
Sets
the
maximum
number
of
concurrent
FLOGI/FDISC
for
this
FCF
to
0.
Command
mode:
VLAN
[no]
fcf
enable
Enables
or
disables
the
VLAN
as
Fibre
Channel
Forwarding
VLAN.
The
default
setting
is
disabled
.
Command
mode
:
VLAN
show
fcf
Displays
FCF
information.
For
details,
see
Command
mode:
All
Содержание RackSwitch G8332
Страница 20: ...20 G8332 Command Reference for ENOS 8 4 ...
Страница 32: ...32 G8332 Command Reference for ENOS 8 4 ...
Страница 674: ...674 G8332 Command Reference for ENOS 8 4 ...
Страница 708: ...708 G8332 Command Reference for ENOS 8 4 ...
Страница 732: ...732 G8332 Command Reference for ENOS 8 4 ...
Страница 750: ...750 G8332 Command Reference for ENOS 8 4 ...
Страница 764: ...764 G8332 Command Reference for ENOS 8 4 Russia Electromagnetic Interference EMI Class A statement ...
Страница 765: ... Copyright Lenovo 2016 Appendix C Notices 765 People s Republic of China Class A electronic emission statement ...
Страница 766: ...766 G8332 Command Reference for ENOS 8 4 Taiwan Class A compliance statement ...
Страница 776: ...776 G8332 Command Reference for ENOS 8 4 ...